GE
GE TEY215 Bolt-On Circuit Breaker 15 A 277/480 V AC 2-Pole
Bolt-on thermal-magnetic breaker rated 15 A at 277/480 V AC with 14 kA interrupting capacity for GE AE lighting panels
- TypeCircuit Breakers
- Reliable 15 A circuit protection for 277/480 V AC systems
- 14 kA interrupting rating handles high fault currents safely
- Bolt-on mounting fits GE AE lighting panels directly
- Thermal-magnetic trip with fixed 575 A instantaneous setting
- Compact 5.25 in frame saves panelboard space
Bolt-On Breaker for GE AE Panels
This 15 A two-pole circuit breaker mounts directly onto GE AE lighting panels using a bolt-on connection. It provides standard thermal-magnetic protection for single-phase AC circuits rated at 277/480 V and DC circuits up to 250 V. The moulded case unit fits a 125 A frame size and accepts lug terminals for secure wiring.
Replaces Worn TEY Series Units
Electricians swap this breaker into existing GE TEY panelboards when an older device trips repeatedly or fails inspection. The fixed instantaneous trip point of 575 A matches the original specification, so coordination with downstream devices remains unchanged. It is not suited for panels that require adjustable trip settings or a different frame size.
Limited to 14 kA Interrupting Rating
The 14 kA AIR rating at 277/480 V AC defines the maximum fault current this breaker can safely interrupt. Systems with available short-circuit current above that level need a higher-rated device. The bolt-on mounting style also prevents use in plug-in or DIN-rail panelboards, so verify the panelboard type before ordering.
Highlights
- Reliable 15 A circuit protection for 277/480 V AC systems
- 14 kA interrupting rating handles high fault currents safely
- Bolt-on mounting fits GE AE lighting panels directly
- Thermal-magnetic trip with fixed 575 A instantaneous setting
- Compact 5.25 in frame saves panelboard space
Specifications
| Brand | GE |
|---|---|
| Type | Circuit Breakers |
Questions about this item
What panelboard space does the 5.25 in height and 2 in width require?
The breaker occupies a standard two-pole slot in a GE AE lighting panelboard with bolt-on mounting rails.
How is the bolt-on connection secured and which torque value avoids loose lugs?
Align the breaker feet with the panelboard bus, press firmly until seated, then torque the terminal lug to the value marked on the breaker label.
When should the thermal-magnetic trip unit be replaced after a 575 A instantaneous trip event?
Inspect contacts for discolouration after any trip above 575 A; replace the breaker if pitting or overheating signs are visible.