GE
GE CR463L20AJA 120V AC Electrically Held Contactor 2P 30A
Controls LED, tungsten and fluorescent lighting circuits with a 120 V AC coil and 2-pole, 30 A inductive rating
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Controls LED circuits up to 10 A
- Handles tungsten loads up to 20 A
- Switches fluorescent lighting at 30 A
- Operates on 110/115-120 V AC coil
- Delivers 1 hp at 120 V AC single phase
GE CR463L20AJA Lighting Contactor
The GE CR463L20AJA is a 120V AC electrically held contactor designed for lighting control circuits. It serves electricians and facility managers who need reliable switching for tungsten, fluorescent or LED loads in commercial or industrial installations. The two-pole, non-reversing unit operates from a 110/115-120V AC coil and fits the CR460 series form factor.
Sustained Load Behaviour
Under continuous operation the contactor carries a 30 A inductive full-load current and a 30 A fluorescent lighting rating. Tungsten loads are rated at 20 A while LED drivers are rated at 10 A, reflecting the higher inrush characteristics of each technology. The 1 hp single-phase rating at 120V AC and 2 hp at 240V AC indicate the motor-load capability when the same poles switch small motors.
Build and Connections
The transparent housing provides visual confirmation of contact status without removing a cover. With no integral enclosure the unit is intended for mounting inside a suitable panel or cabinet supplied by the installer. Screw terminals accept the power and control conductors, and the open frame design allows straightforward wiring access during commissioning and maintenance.
Highlights
- Controls LED circuits up to 10 A
- Handles tungsten loads up to 20 A
- Switches fluorescent lighting at 30 A
- Operates on 110/115-120 V AC coil
- Delivers 1 hp at 120 V AC single phase
Specifications
| Brand | GE |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How much heat does the 30 A inductive rating generate during all-day operation?
The contactor carries a 30 A inductive load at 120 V AC; heat rise follows standard magnetic-contactor design for continuous duty.
What control voltage must my circuit supply to energise the coil?
The coil operates on 110/115-120 V AC, so a compatible 120 V AC control source is required.
Can I use this 2-pole unit with an existing single-phase 240 V motor starter?
It is rated 2 hp at 240 V AC single-phase and 1 hp at 120 V AC single-phase, matching many legacy motor starters.