A single-pole manual motor starter with toggle operation rated for 16 A and 1 hp at 120 V or 240 V AC
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Manual motor starter rated for 16 A single-phase circuits
- Toggle operator provides direct on/off control
- Thermal overload protection safeguards connected equipment
- Compact 2.63 in depth fits tight panel spaces
- NEMA 1 enclosure suits indoor installations
GE CR101Y1 Manual Motor Starter
The GE CR101Y1 is a single-phase manual motor starter rated for 16 A and a maximum of 230 V AC/DC. It uses a toggle operator and provides thermal overload protection in a NEMA 1 enclosure. This starter suits installers who need basic on-off control for small single-phase motors up to 1 hp at 120 V or 240 V.
Single-phase 16 A toggle control
The device handles one pole and one phase only, so it cannot protect three-phase loads or circuits above 16 A. Its NEMA 1 rating limits use to indoor, dry locations and the thermal overload requires a separate heater element matched to the motor. The 2.63 in depth and 4.16 in height fix the panel space needed.
Replaces fractional-hp starters without overload
It upgrades from a plain toggle switch by adding thermal overload protection for motors up to 1 hp. The jump is worth it when code or insurance demands overload protection on 120 V or 240 V single-phase loads. Buyers needing three-phase control, higher current, or outdoor enclosures must select a different starter.
Highlights
- Manual motor starter rated for 16 A single-phase circuits
- Toggle operator provides direct on/off control
- Thermal overload protection safeguards connected equipment
- Compact 2.63 in depth fits tight panel spaces
- NEMA 1 enclosure suits indoor installations
Specifications
| Brand | GE |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Should I choose the 120 V or 240 V single-phase rating for my motor?
Both ratings deliver 1 hp; pick the one that matches your supply voltage.
What does the 16 A current rating mean once the starter is installed?
It is the maximum continuous AC current the contacts can carry without tripping the thermal overload.
How does the 230 V AC/DC maximum voltage rating cap what I can connect?
Do not apply more than 230 V AC or DC across the starter; higher voltages exceed its insulation rating.