We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

GE

GE Bolt-On Circuit Breaker TEY250 2-Pole 50 A 277/480 V AC 14 kA

SKU CH-BJ1D-FGRN8

A 50 A, 2-pole bolt-on breaker rated 277/480 V AC with a 14 kA interrupting capacity for GE AE lighting panels

  • TypeCircuit Breakers
  • 50 A protection for 277/480 V AC systems
  • 14 kA interrupting rating handles high fault currents
  • Bolt-on mounting fits GE AE lighting panels directly
  • Thermal-magnetic trip gives reliable overload and short-circuit response
  • Two-pole design controls both lines in single-phase circuits

GE Bolt-On Breaker 50 A 277/480 V

This GE TEY250 is a two-pole molded-case circuit breaker rated for 50 amps at 277/480 volts AC with a 14 kA interrupting rating. It uses a bolt-on mounting style for GE AE lighting panels and features a thermal-magnetic trip mechanism with a fixed instantaneous setting. The frame size is 125 A and the high amp trip setting is 250 A. A lug terminal connection accepts conductors for standard panel wiring.

Suited for GE AE panels needing 50 A protection

Electricians wiring GE AE lighting panelboards will find this breaker matches the required bolt-on footprint and voltage rating. It is not suitable for panels that accept only plug-on breakers or for systems requiring a higher interrupting capacity than 14 kA at 277/480 V AC. Buyers needing a different amperage, pole count, or DC-only rating should select another model. The single-phase connection and Any phase configuration limit use to compatible panel layouts.

Bolt-on install in GE AE panelboards

Installation consists of aligning the breaker with the panelboard bus stabs and securing it with the mounting bolt, then tightening the lug terminals to the specified torque. The fixed instantaneous trip means no field adjustment is possible, so coordination studies must use the published 250 A high amp setting. Common issues include mismatched panel series, incorrect lug torque, and attempting to mount in non-GE or plug-on style enclosures.

Highlights

  • 50 A protection for 277/480 V AC systems
  • 14 kA interrupting rating handles high fault currents
  • Bolt-on mounting fits GE AE lighting panels directly
  • Thermal-magnetic trip gives reliable overload and short-circuit response
  • Two-pole design controls both lines in single-phase circuits

Specifications

BrandGE
TypeCircuit Breakers

Questions about this item

Does the buyer need a GE AE lighting panel with a bolt-on mounting rail to install this breaker?

Yes, the TEY250 is designed for bolt-on mounting in GE AE lighting panels and requires a compatible panel rail and bus connection.

Will this 50 A, 2-pole breaker coordinate with an existing 125 A frame TEY main breaker in the same panel?

The 50 A thermal-magnetic trip unit operates within the 125 A TEY frame size, allowing selective coordination when installed downstream of a 125 A TEY main breaker.

How can the installer verify the breaker trips correctly after wiring it to a 277/480 V AC circuit?

Apply rated current to confirm the thermal element opens on sustained overload and the fixed instantaneous trip operates at 250 A, observing the handle move to the tripped position.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.