GE
GE 15D21G002 Replacement Coil NEMA 110/115-120V AC video accessory
Replacement coil for NEMA contactors and starters, 110/115-120V AC, 24 VA, 50/60 Hz
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Reliable control with 110/115-120V AC coil voltage
- Fits existing NEMA 0, 00, 1 contactors and starters
- 24 VA coil power keeps energy use low
- Works on 50/60 Hz supplies worldwide
- Brand-new GE component ready for immediate install
Replacement Coil for NEMA Contactors
This GE 15D21G002 replacement coil operates at 110/115-120V AC with a 50/60 Hz frequency rating. It fits NEMA Size 0, 00 and 1 contactors and starters across the 200-Line and 300-Line series. The coil draws 24 VA and is supplied in a transparent finish. It is designed for industrial electrical control and automation panels.
Thermals, noise and power draw in normal use
The coil consumes 24 VA during energised operation at the rated voltage and frequency. No active cooling or moving parts are present, so the component runs silently. Heat output is limited to the inherent losses of the electromagnetic winding under normal duty cycles.
Coil voltage and NEMA compatibility
The single specification that decides fit is the 110/115-120V AC coil voltage combined with NEMA Size 0, 00, 1 compatibility for 200-Line and 300-Line contactors and starters. Buyers who need a different control voltage or a larger NEMA frame size cannot use this part.
Highlights
- Reliable control with 110/115-120V AC coil voltage
- Fits existing NEMA 0, 00, 1 contactors and starters
- 24 VA coil power keeps energy use low
- Works on 50/60 Hz supplies worldwide
- Brand-new GE component ready for immediate install
Specifications
| Brand | GE |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How do I install the 15D21G002 coil into a NEMA Size 1 contactor and what step is often missed?
Power off the circuit, remove the old coil, seat the new 110/115-120V AC coil firmly in the frame, then verify the 50/60 Hz rating matches your supply before re-energising.
What maintenance or replacement will the 15D21G002 coil need after extended service?
Inspect the transparent housing for discolouration or cracking and replace the coil if the 24 VA winding shows open circuit or overheating signs.
What limit appears first when the 15D21G002 coil runs continuously at 120V AC?
The 24 VA coil power rating defines the thermal limit; sustained operation at rated voltage will reach temperature rise limits before voltage or frequency margins are exceeded.