Fluke
Fluke VR1710 Voltage Recorder Single Phase 70 to 300V
Single-phase voltage recorder captures AC data from 70 to 300 V with ±0.5 % accuracy and one-second sampling
- TypeDigital Multimeters
- Records voltage trends over time with 1-second sampling
- Measures single-phase AC from 70 V to 300 V
- Delivers ±0.5 % AC voltage accuracy
- Visual light alert flags out-of-range events instantly
- Calibration certificate available separately for traceable compliance
Single-Phase Voltage Logger
The Fluke VR1710 records single-phase AC voltage between 70 and 300 V with a stated accuracy of .5 percent. It is intended for electricians and facility technicians who need a continuous record of supply quality rather than a spot measurement.
Sustained Monitoring Behaviour
The logger samples at a minimum interval of one second, building a timeline that reveals sags, swells and outages over long periods. It has no current channels, so it cannot capture load profiles or power-factor data.
Thermals Noise And Power
The unit is a passive measurement device with no internal fan, moving parts or active cooling requirement. It draws negligible power from the circuit under test and produces no audible noise during operation.
Highlights
- Records voltage trends over time with 1-second sampling
- Measures single-phase AC from 70 V to 300 V
- Delivers ±0.5 % AC voltage accuracy
- Visual light alert flags out-of-range events instantly
- Calibration certificate available separately for traceable compliance
Specifications
| Brand | FLUKE |
|---|---|
| Type | Digital Multimeters |
Questions about this item
How much power does the VR1710 draw when logging continuously all day?
The logger records single-phase AC voltage from 70 to 300 V with ±0.5 % accuracy at a minimum 1-second sampling rate, drawing negligible power from the measured circuit itself.
What wiring or accessories must I already have to start recording with the VR1710?
You need access to a single-phase AC supply within the 70–300 V range and suitable test leads or clips to connect the recorder’s voltage input terminals safely.
Will the VR1710 work alongside my older Fluke multimeters without calibration conflicts?
Each VR1710 operates independently; its ±0.5 % AC voltage accuracy is traceable, and a separate calibration certificate is available if your quality system requires matched calibration across instruments.