Fluke TP2 Test Probes 10A Black Red 1000V
Pair of black and red test probes rated 10 A and 1000 V CAT III / 600 V CAT IV for Fluke multimeters
- TypeAssortments & Kits
- Rated for 1000 V CAT III and 600 V CAT IV safety
- Handles up to 10 A continuous current for demanding circuits
- Compatible with Fluke 87V, 179, 289 and many other models
- Black and red probes provide clear polarity identification
- Hand-held and hands-free operation both rated to 1000 V AC/DC
Fluke TP2 test probe set
The Fluke TP2 test probe set supplies a black and a red probe rated for 10 A and 1000 V DC. They carry CAT III 1000 V and CAT IV 600 V safety ratings for handheld and hands-free use. The probes are built for electrical professionals who need reliable contact on live circuits.
Replaces worn or damaged leads on supported meters
The set fits Fluke models including the 83V, 87V, 175, 177, 179, 287, 289, 705, 707Ex, 709, 712 RTD, 787, 787B, 789, T+, T+Pro, T5-600, T5-1000 and TL20. Upgrading is worthwhile when existing probes show cracked insulation, bent tips or intermittent readings that compromise measurement accuracy.
Simple push-on connection
Installation takes seconds: align the shrouded plug and press until it seats firmly. The most common issue is debris in the meter jack preventing a full lock, which can cause high-resistance contacts or safety-rating loss. Inspect and clean the jack before fitting new probes.
Highlights
- Rated for 1000 V CAT III and 600 V CAT IV safety
- Handles up to 10 A continuous current for demanding circuits
- Compatible with Fluke 87V, 179, 289 and many other models
- Black and red probes provide clear polarity identification
- Hand-held and hands-free operation both rated to 1000 V AC/DC
Specifications
| Brand | FLUKE |
|---|---|
| Type | Assortments & Kits |
Questions about this item
What multimeter models do these Fluke TP2 probes connect to?
The probes work with Fluke 175, 177, 179, 287, 289, 705, 707Ex, 709, 712 RTD, 787, 787B, 789, 83V, 87V, T+, T+Pro, T5-1000, T5-600 and TL20 meters.
How do I install the probes so the CAT III 1000 V rating stays valid?
Push each probe firmly into the meter's input jacks until the shroud seats fully; a loose fit lowers the safety rating to CAT IV 600 V.
When should I replace the probe tips on this 10 A set?
Replace the tips when the metal shows pitting, the insulation cracks or the probe no longer makes solid contact during a 10 A measurement.