Fluke
Fluke TL175 Retractable Tip Test Lead 56 in Red/Black
Retractable test leads with removable 4 mm lantern tips, silicone insulation rated CAT III 1000 V and CAT IV 600 V, 10 A maximum current, 56 in. length, operating from -4 °F to 131 °F
- TypeAngle, Pitch & Slope Locators
- Retractable tips protect probe points when stored
- 56 inch silicone leads stay flexible to -4°F
- CAT III 1000V and CAT IV 600V ratings for mains work
- 10 A / 1000 VAC capacity covers most bench tasks
- Universal 4 mm shrouded banana plugs fit all standard instruments
Test Lead with Retractable Tips
The Fluke TL175 is a pair of test leads built for electrical measurement tasks. Retractable tip covers protect the probe points when not in use. They connect to any instrument that accepts standard 4 mm shrouded banana plugs. The set includes removable 4 mm lantern tips that thread onto the lead ends.
Silicone Insulation and Safety Ratings
Each lead uses 18 gauge wire with silicone insulation rated from -4 to 131 degrees F. Safety ratings cover CAT III 1000 V, CAT IV 600 V and CAT II 1000 V. The 56 inch length gives reach across a workbench or inside a panel. Universal input plugs ensure a secure fit on compatible meters.
Rated for 10 Amps and 1000 VAC
Maximum current is 10 A and maximum voltage is 1000 VAC. The retractable design reduces the risk of accidental shorts during storage. Silicone insulation remains flexible in cold environments. A one year manufacturer warranty covers the leads.
Highlights
- Retractable tips protect probe points when stored
- 56 inch silicone leads stay flexible to -4°F
- CAT III 1000V and CAT IV 600V ratings for mains work
- 10 A / 1000 VAC capacity covers most bench tasks
- Universal 4 mm shrouded banana plugs fit all standard instruments
Specifications
| Brand | FLUKE |
|---|---|
| Type | Angle, Pitch & Slope Locators |
| Shipping weight | 0.91 kg |
| Package size | 76 × 76 × 76 mm |
Questions about this item
What safety rating does the CAT III 1000 V marking on these TL175 leads cap in practice?
The leads are rated CAT III 1000 V and CAT IV 600 V, so they are approved for 1000 V measurement circuits and 600 V at the service entrance.
What plug diameter do the shrouded banana plugs on the TL175 need to fit a meter input?
The universal input plugs are standard 4 mm shrouded banana plugs compatible with all instruments accepting that size.
How do you install the removable lantern tips on the TL175, and what step is often missed?
Thread each 4 mm lantern tip onto the lead tip until it seats firmly; the step often missed is ensuring the tip is fully tightened before use.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Lab Safety Supply Inc 667123 24 Well Tissue Culture Plate w/Lid PK50
- Assortments & Kits
Lab Safety Supply Inc 11L806 2mL Pipet Individually Wrapped PK600
- Assortments & Kits