Measures differential and static pressure, air velocity and flow up to 16,000 fpm and 99,999 cfm with ±1 % accuracy
- TypePressureTransmitters
- Measures differential and static pressure up to 16 in wc
- Displays air velocity and flow readings up to 99,999 cfm
- Handheld digital manometer with 5 digit LCD for clear readings
- Powered by included batteries for immediate field use
- NIST traceable certificate not included with this model
Airflow Meter and Micromanometer
The Fluke 922 is a handheld digital manometer designed for HVAC technicians and facility engineers who need to verify ventilation performance. It measures differential and static pressure, air velocity and volumetric flow in a single instrument. The tool is powered by included batteries and presents readings on a five-digit LCD.
Suited for balancing and commissioning work
This meter suits professionals who require simultaneous pressure, velocity and flow data during system balancing or filter testing. It is not intended for buyers who need wireless data logging or a NIST-traceable calibration certificate supplied with the unit. Users requiring a separate calibration document should arrange that service independently.
Pressure range and accuracy
The instrument covers a pressure span of -16 to 16 in wc with a stated accuracy of +/-1 percent. Maximum measurable air velocity reaches 16,000 fpm, while volumetric flow reads up to 99,999 in cfm, cubic metres per hour or litres per second. These limits define the operating envelope for duct and grille traverses.
Highlights
- Measures differential and static pressure up to 16 in wc
- Displays air velocity and flow readings up to 99,999 cfm
- Handheld digital manometer with 5 digit LCD for clear readings
- Powered by included batteries for immediate field use
- NIST traceable certificate not included with this model
Specifications
| Brand | FLUKE |
|---|---|
| Type | PressureTransmitters |
Questions about this item
What pressure range does the Fluke 922 cover and what accuracy does it hold?
It reads differential and static pressure from -16 to 16 in wc with a stated accuracy of ±1 %.
What hose size does the 1/4 in barb on the Fluke 922 accept?
The process connection is a 1/4 in hose barb for standard flexible tubing.
How is the Fluke 922 powered and what step do users often skip?
Batteries are included; insert them and verify the 5 digit LCD powers up before taking readings.