Fluke
Fluke 789 ProcessMeter measurement tool
Measures, sources and simulates 4-20 mA signals with a built-in 24 V loop supply and 250 Ohm Hart resistor
- 1000 V overload protection on volts, ohms and frequency
- 24 V loop supply powers transmitters without external source
- 50 hours typical measurement time on one 9 V alkaline battery
- 25 % manual step plus auto step and auto ramp on mA output
- 0 % and 100 % buttons toggle between 4 and 20 mA for quick span check
Fluke 789 ProcessMeter for loop testing
The Fluke 789 ProcessMeter combines standard digital multimeter functions with the ability to measure, source and simulate 4-20 mA signals. A built-in 24 V loop supply powers the circuit during testing. It is suited for technicians who maintain process instrumentation in the field.
Practical limits of the 4-20 mA interface
Current measurement covers 0 to 30 mA DC with 150 V overload protection on the mA terminals, backed by a 440 mA 1000 V fuse. Voltage, resistance and frequency inputs withstand 1000 V overload. Sourcing 12 mA typically runs for 12 hours on one 9 V alkaline battery, while measurement alone reaches about 50 hours.
Build quality and daily connector implications
A clear LCD with backlight remains readable in low light. Manual 25-percent step, auto step and auto ramp functions speed up mA output adjustments. A selectable 250-Ohm Hart resistor is built in. Dedicated 0 and 100-percent buttons toggle between 4 and 20 mA sourcing for quick span checks without menu navigation.
Highlights
- 1000 V overload protection on volts, ohms and frequency
- 24 V loop supply powers transmitters without external source
- 50 hours typical measurement time on one 9 V alkaline battery
- 25 % manual step plus auto step and auto ramp on mA output
- 0 % and 100 % buttons toggle between 4 and 20 mA for quick span check
Specifications
No published specifications for this item yet.
Questions about this item
Should I choose the 4 mA or 20 mA sourcing mode for a quick span check?
Use the 0 % and 100 % buttons to toggle between 4 mA and 20 mA sourcing for a quick span check.
What does the 30 mA DC current measurement range mean when I am testing a live loop?
You can measure 0 to 30 mA DC directly in the loop without an external shunt.
How does the 24 V loop supply interact with the built-in 250 Ohm HART resistor?
The selectable 250 Ohm HART resistor is built in and works with the 24 V loop supply for HART communication.