Flowline
Flowline LU83-5101 ultrasonic level sensor 26.2 ft range
Non-contact ultrasonic sensor measures corrosive or ultrapure liquids up to 26.2 ft with ±0.2 % accuracy and 2-wire 28 V DC output
- TypeLevel Measurement
- Non-contact measurement avoids media contamination with PVDF construction
- 2 ft range covers deep tanks and vessels
- ±0.2 % accuracy delivers reliable level data
- 2-wire 28 V DC loop simplifies wiring and power
- Operates from -7 °F to 140 °F for harsh environments
Flowline LU83-5101 ultrasonic transmitter
The Flowline LU83-5101 is a non-contact ultrasonic level sensor built for continuous measurement in tanks and vessels. Its PVDF transducer resists corrosive, sticky, waste and ultrapure liquids across a 26.2 ft range with a 3 in beam width.
Suits process engineers monitoring aggressive media
This unit fits applications that need a 2 in NPT mount, 30 psi pressure rating and media temperatures from -7 to 140 °F. It is not for installations requiring a smaller dead band than 8 in, a different connection size or an operating frequency other than 50 kHz.
Range and accuracy drive selection
The sensor delivers a 314.4 in measurement span with ±0.2 percent of range accuracy and 0.039 in spatial resolution. Buyers whose process demands a longer span, tighter accuracy or a higher voltage limit than 28V DC should evaluate other models.
Highlights
- Non-contact measurement avoids media contamination with PVDF construction
- 2 ft range covers deep tanks and vessels
- ±0.2 % accuracy delivers reliable level data
- 2-wire 28 V DC loop simplifies wiring and power
- Operates from -7 °F to 140 °F for harsh environments
Specifications
| Brand | Flowline |
|---|---|
| Type | Level Measurement |
Questions about this item
How do I mount the LU83-5101 and what is the common installation mistake?
Thread the 2 in NPT fitting into a tank opening; the step often missed is keeping the sensor face at least 8 in above the highest liquid level to avoid the dead band.
What maintenance will the LU83-5101 need over time?
The PVDF antenna resists corrosive, sticky and ultrapure liquids, so only periodic visual checks for build-up on the 2 3/8 in face are required.
What limit appears first during continuous operation of the LU83-5101?
The 30 psi maximum operating pressure or the 140 °F media temperature ceiling will be reached before the 28 V DC supply limit under sustained use.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
PowerWarehouse BenQ 5J.J2G01.001 DLP Replacement Lamp
- Lamps
- 2000