Fernco Inc.
Fernco Inc. 1056-22 Conduit 2.800
Elastomeric PVC flexible coupling for 2 inch conduit, 2.800 inch length
- MaterialElastomeric PVC
- TypeConduit Fittings
- Length2.800
- Elastomeric PVC construction resists corrosion and ground movement
- Flexible coupling joins two-inch nominal pipes without rigid alignment
- 800 inch overall length fits standard conduit spacing
- Meets ASTM standards for reliable underground installations
Fernco 1056-22 Conduit for 2-Inch Pipe
The Fernco 1056-22 is a flexible conduit coupling designed to join two sections of 2-inch nominal pipe. It is made from black elastomeric PVC and suits installers who need a watertight, corrosion-resistant joint in drainage or electrical conduit systems. The coupling measures 2.800 inches in overall length and accepts pipe outside diameters of 2 inches, 2-3/8 inches and 2-7/8 inches on both ends. Buyers who require rigid metal conduit or larger diameter connections will need a different fitting type.
Thermals Noise and Power Draw in Normal Use
As a passive PVC fitting, this conduit coupling draws no electrical power and generates no heat or acoustic noise during operation. It relies on the natural flexibility of the elastomeric material to maintain a seal under ground movement or vibration. The material resists chemical attack and UV exposure without active cooling or energy input. Installers should verify that the pipe outside diameters fall within the accepted range for a secure fit.
Highlights
- Elastomeric PVC construction resists corrosion and ground movement
- Flexible coupling joins two-inch nominal pipes without rigid alignment
- 800 inch overall length fits standard conduit spacing
- Meets ASTM standards for reliable underground installations
Specifications
| Brand | FERNCO, INC. |
|---|---|
| Material | Elastomeric PVC |
| Type | Conduit Fittings |
| Length | 2.800 |
Questions about this item
How do you install the 1056-22 flexible coupling onto a 2-inch conduit, and what step is often missed?
Slide the coupling over each pipe end, centre it on the joint, then tighten the stainless-steel clamps evenly; the step often missed is confirming both pipe outside diameters match the 2 3/8 in and 2 7/8 in ranges before clamping.
What maintenance or replacement will the elastomeric PVC coupling need over time?
Inspect the PVC body and clamps annually for cracks, hardening or corrosion; replace the coupling if the elastomer loses flexibility or the clamps no longer hold the 3 1/2 in overall length securely.
Also in this aisle
People compared these