We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

FASCO

FASCO A164 Blower 3000 RPM 120V 0.8 A 81 cfm

SKU CH-HV2R-1YWKN

120 V shaded-pole blower delivers 81 cfm at 3 000 RPM for Lennox furnace model 7021-9593

  • ColorTransparent
  • Runs at 3000 RPM for strong airflow
  • Delivers 81 cfm at zero static pressure
  • Operates on 120V AC single-phase power
  • Draws only 0.8 A for efficient operation
  • Withstands inlet temperatures up to 400 Degrees F

FASCO A164 blower for Lennox furnaces

This FASCO A164 blower is a direct-drive replacement component built for Lennox heating systems. It runs on 120V AC single-phase power at 60 Hz and draws 0.8 A through wire leads. The shaded-pole motor is rated for insulation class B and spins at a maximum of 3000 RPM.

Suits Lennox furnace repairs.

The unit matches Lennox model 7021-9593 and fits furnace applications where a single-speed, direct-drive blower is specified. It is not suited for systems that require multi-speed operation, variable airflow control, or a different voltage supply.

81 cfm airflow with 1 in wc static pressure limit

At zero static pressure the blower delivers 81 cfm of air. The maximum static pressure rating is 1 in wc, so airflow will drop as duct resistance approaches that value. The motor tolerates inlet air temperatures up to 400 degrees F, providing headroom for normal furnace operating conditions.

Highlights

  • Runs at 3000 RPM for strong airflow
  • Delivers 81 cfm at zero static pressure
  • Operates on 120V AC single-phase power
  • Draws only 0.8 A for efficient operation
  • Withstands inlet temperatures up to 400 Degrees F

Specifications

BrandFASCO
ColorTransparent

Questions about this item

What voltage supply does the FASCO A164 blower require?

The blower runs on 120V AC single-phase power at 60 Hz and draws 0.8 A.

Can this blower replace a Lennox 7021-9593 unit directly?

Yes, it is listed as a direct replacement for Lennox model 7021-9593.

How can I confirm the blower is delivering its rated airflow after installation?

At zero static pressure it should move 81 cfm; measuring airflow at the 2 1/4 in outlet verifies performance.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.