Fans
Fans ebmpapst A6D630-AD01-01 190W axial blower
New axial blower moves up to 35000 m³/h at 190 W, 400 VAC three-phase, 50 Hz, speeds of 1320 and 1050 min⁻¹, max back-pressure 220 Pa, ambient range –40 °C to 60 °C
- 190 W three-phase motor delivers 35000 m³/h airflow
- 400 VAC 50 Hz supply suits industrial power systems
- 1320 rpm nominal speed with 1670 rpm maximum safe limit
- Operates from -40 °C to 60 °C ambient range
- Steel housing and forced electronic cooling ensure durability
Industrial blower for HVAC systems
The ebmpapst A6D630-AD01-01 is a new axial blower rated at 190 W nominal power. It delivers airflow up to 35000 m³/h for hot or cold air exchange in commercial equipment. The unit suits installers who need high-volume air movement through heat exchangers in ventilation or process-cooling applications.
Steel housing with three-phase motor
A sturdy steel plate encloses the compact external-rotor motor M4D138-LA running on three-phase 400 VAC at 50 Hz in Y connection. Speed control from 0 to 100 % is available via analog or serial interface for simple integration into building-management or machine-control cabinets. The blower mounts directly in ductwork or on equipment panels.
Thermal range and electrical profile
Operating ambient spans -40 °C to 60 °C with a maximum safe speed of 1670 min⁻¹ at 70 °C. At 50 Hz the fan draws 2.95 A and 1750 W at 1050 min⁻¹, producing 140 Pa back pressure; at 60 Hz it draws 4.78 A and 2630 W at 1320 min⁻¹ with 220 Pa. Starting current reaches 6.5 A or 19 A depending on supply frequency.
Highlights
- 190 W three-phase motor delivers 35000 m³/h airflow
- 400 VAC 50 Hz supply suits industrial power systems
- 1320 rpm nominal speed with 1670 rpm maximum safe limit
- Operates from -40 °C to 60 °C ambient range
- Steel housing and forced electronic cooling ensure durability
Specifications
No published specifications for this item yet.
Questions about this item
What does the 400 VAC three-phase connection limit in practice?
It restricts use to industrial three-phase 400 V supplies; single-phase or lower-voltage mains cannot drive the motor.
What mounting provisions does the steel-plate housing provide?
The sturdy steel plate body is designed for direct bracket or flange mounting in HVAC enclosures; no separate frame kit is mentioned.
How is the 100 % speed control wired, and what step is often missed?
Connect the analog or serial control interface to a 0–10 V or PWM source and ensure the control reference shares ground with the fan electronics; omitting the common ground is the typical error.