Fans
Fans D2E160-AH02-15 160MM 230V 550W Blower
160 mm centrifugal blower runs on 230 V AC at 50 or 60 Hz, delivering 2500 rpm and 550 W for ABB ACS800 inverter cooling
- Designed for ABB ACS800 inverter cooling
- 160 mm centrifugal blower runs on 230 VAC 50/60 Hz
- Dual-speed motor delivers 2500/2400 min-1 with 550/730 W input
- Operates from -25 °C to 90 °C ambient temperature
- Airflow up to 35000 m3/h with 12 µF 400 VDB capacitor
Industrial blower for ABB inverter cooling
The D2E160-AH02-15 is a 160 mm centrifugal blower built for ABB ACS800 drives. It runs on 230 VAC at 50 or 60 Hz and draws 2.45 A at 50 Hz or 3.2 A at 60 Hz. The motor uses a 12 µF capacitor rated at 400 VDB. It suits plants and facilities that need direct replacement airflow for drive enclosures.
Sustained operation across wide temperature range
At 50 Hz the impeller spins at 2500 min⁻¹ with 550 W input; at 60 Hz it runs at 2400 min⁻¹ with 730 W input. Minimum back pressure holds at 400 Pa and 390 Pa respectively. The unit is rated for continuous ambient temperatures from -25 °C up to 90 °C at 50 Hz and 50 °C at 60 Hz, supporting long duty cycles in harsh environments.
Fixed voltage and frequency interface limits
The blower only accepts 230 VAC single-phase supply at the two stated frequencies. No other voltage, phase count or frequency is supported. Airflow reaches 35000 m³/h under the specified back-pressure conditions. Installations requiring variable-speed control, different supply voltages or lower acoustic output must select an alternative model.
Highlights
- Designed for ABB ACS800 inverter cooling
- 160 mm centrifugal blower runs on 230 VAC 50/60 Hz
- Dual-speed motor delivers 2500/2400 min-1 with 550/730 W input
- Operates from -25 °C to 90 °C ambient temperature
- Airflow up to 35000 m3/h with 12 µF 400 VDB capacitor
Specifications
No published specifications for this item yet.
Questions about this item
How much power does the D2E160-AH02-15 blower draw when running continuously at 230 V and 50 Hz?
At 50 Hz the unit draws 550 W and 2.45 A. At 60 Hz the input rises to 730 W and 3.2 A.
What electrical connection does the D2E160-AH02-15 need to operate?
It requires a 230 VAC supply at 50 or 60 Hz and a 12 µF, 400 VDB motor capacitor.
Will the D2E160-AH02-15 fit the same mounting points as the original fan in my ABB ACS800 inverter?
The blower is built as a direct replacement for the ACS800 series, matching the original 160 mm frame and airflow of 35,000 m³/h.