We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Fans

Fans D2D146-AF02-14 double inlet centrifugal blower

SKU CH-AHKH-SFMF8

Double-inlet centrifugal blower delivers up to 35,000 m³/h airflow at 2100–2200 rpm with 230/400 VAC three-phase power

  • Double-inlet design moves up to 35000 m³/h airflow
  • External rotor motor enables compact housing and forced cooling
  • Operates at 230 VAC or 400 VAC three-phase supply
  • Runs from -25 °C up to 60 °C ambient temperature
  • Steel-plate construction handles 200 Pa minimum back pressure

Industrial double inlet centrifugal blower

The Fans D2D146-AF02-14 is a new double inlet centrifugal blower built for industrial HVAC and ventilation systems. It uses an external rotor motor design that integrates the motor within the impeller for compact installation. The unit suits engineers and maintenance teams specifying original ebm-papst components for air-handling equipment.

230 VAC and 400 VAC three-phase operation

At 50 Hz the blower draws 0.93 A at 230 V or 0.54 A at 400 V, consuming 345 W and turning at 2100 rpm. At 60 Hz current rises to 1.06 A at 230 V or 0.61 A at 400 V, power reaches 410 W and speed increases to 2200 rpm. Starting current peaks at 1.75 A and 1.0 A respectively. Minimum back pressure is rated at 200 Pa for 50 Hz and 240 Pa for 60 Hz.

Steel plate housing with wide temperature range

Sturdy steel plate construction supports continuous operation from -25 °C up to 60 °C at 50 Hz and 45 °C at 60 Hz. The compact external rotor motor layout enables forced electronic cooling without a separate scroll housing. This blower is not suited for applications requiring single-phase supply or airflow beyond 35000 m3/h.

Highlights

  • Double-inlet design moves up to 35000 m³/h airflow
  • External rotor motor enables compact housing and forced cooling
  • Operates at 230 VAC or 400 VAC three-phase supply
  • Runs from -25 °C up to 60 °C ambient temperature
  • Steel-plate construction handles 200 Pa minimum back pressure

Specifications

No published specifications for this item yet.

Questions about this item

How do I wire the three-phase D2D146-AF02-14 for 400 VAC Y connection?

Connect the three phases to the motor terminals in star (Y) configuration for 400 VAC 50 Hz operation; the motor draws 0.54 A at 2100 rpm and 345 W. Ensure the supply matches 400 VAC three-phase.

What bearing maintenance does the external rotor motor need over time?

The external rotor motor uses sealed bearings lubricated for life; no relubrication is required. Monitor for increased noise or vibration which indicates bearing wear and plan full unit replacement.

At what ambient temperature does the blower reach its thermal limit first during continuous duty?

At 400 VAC 60 Hz the maximum ambient temperature is 45 °C; at 230 VAC 60 Hz it is also 45 °C. Operation above these temperatures risks motor overheating and reduced lifespan.