We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

ETCR

ETCR ETCR2000A+ Clamp Earth Resistance Tester 0.01-200ohm 65x32mm 99 Data Sets

SKU CH-JF0A-T3ZHQ MPN ETCR2000A

Measures ground resistance from 0.01 to 200 ohms with a 65 by 32 mm clamp jaw and stores 99 data sets

  • TypeTest Equipment
  • Color/FinishRed
  • Item Count1 pack
  • Selling UnitBox
  • Parts3 Years
  • Labor1 Year
  • Measures ground resistance without disconnecting wires for safer testing
  • Stores up to 99 data sets for later review
  • Jaw opens 65 by 32 mm to fit large conductors
  • Built-in alarm alerts when readings exceed set limits
  • Resolution of 0.01 ohm across a 0.01 to 200 ohm range

Digital Clamp Earth Resistance Tester

The ETCR ETCR2000A+ is a clamp-on digital tester designed for measuring ground resistance and loop resistance without disconnecting ground wires or using auxiliary electrodes. It serves electricians and technicians working in power, telecommunications, meteorology, oil fields, architecture and industrial electrical equipment. The instrument stores up to 99 data sets for later review. An integrated alarm function alerts the user when readings exceed a set threshold.

Measurement Range and Jaw Limits

Resistance is measured from 0.01 ohm up to 200 ohm with a display range of 1 to 199 ohm. The clamp jaw opening measures 65 by 32 millimetres, which sets the maximum conductor size that can be encircled for a valid reading. Measurements rely on a closed loop path; isolated electrodes without a return circuit cannot be tested with this method. Accuracy and resolution are fixed by the instrument design and cannot be adjusted by the operator.

Pre-Purchase Setup Checks

Confirm that the conductors you intend to test fit within the 65 by 32 millimetre jaw opening. Verify that the grounding system under test forms a complete loop so the clamp can induce and sense current without auxiliary stakes. Ensure the expected resistance values fall within the 0.01 to 200 ohm range. Check that the 99-record memory capacity meets your data-logging needs for a typical job.

Highlights

  • Measures ground resistance without disconnecting wires for safer testing
  • Stores up to 99 data sets for later review
  • Jaw opens 65 by 32 mm to fit large conductors
  • Built-in alarm alerts when readings exceed set limits
  • Resolution of 0.01 ohm across a 0.01 to 200 ohm range

Specifications

BrandETCR
ModelETCR2000A+
TypeTest Equipment
Color/FinishRed
Item Count1 pack
Selling UnitBox
Parts3 Years
Labor1 Year

Questions about this item

What does the 0.01-200 ohm range mean for everyday ground-loop testing?

The tester reads from 0.01 ohm up to 200 ohm, so it covers both very low-resistance bonds and higher-resistance earth electrodes without changing instruments.

How does the clamp-on design affect a measurement on a live grounding system?

The 65x32 mm jaw clamps around the conductor, letting you measure loop resistance without disconnecting the ground wire or driving auxiliary electrodes.

What does the 99-set memory limit mean for field surveys?

You can store up to 99 readings internally before you need to offload or overwrite data, which suits typical single-day inspection routes.