ETCR
ETCR 6200 AC/DC Leakage Current Clamp Meter 0mA~60.0A electrician tool
Measures AC/DC leakage current from 0 mA to 60.0 A with 1 mA resolution, stores 99 readings and fits conductors up to 25 mm × 30 mm
- TypeTest Equipment
- Color/FinishRed
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- Measures AC/DC leakage current up to 60.0A without breaking the circuit
- 1mA resolution detects small leakage currents in automotive and electrical systems
- Stores 99 reading groups for later review and fault diagnosis
- 25mm x 30mm clamp jaw fits around conductors up to 600V line voltage
- ±2%rdg±5dgt accuracy ensures reliable measurements for troubleshooting
AC/DC Leakage Current Measurement
The ETCR 6200 clamp meter measures both AC and DC leakage current from 0mA to 60.0A without breaking the circuit. It uses a 25mm by 30mm CT jaw for non-contact readings on conductors carrying up to 600V line voltage. Resolution is 1mA with a stated accuracy of ±2%rdg±5dgt. The meter stores up to 99 measurement groups for later review.
Automotive electrical diagnostics
Technicians troubleshooting vehicle dark current, parasitic drain, starter motor draw or alternator charging current will find the range and jaw size practical. The tool is not suited for work on conductors larger than the 25mm by 30mm aperture or for installations exceeding 600V line voltage. Users needing higher current ranges or smaller jaw profiles should consider other instruments.
60.0A maximum measurement range
The single specification that decides fit is the 0mA to 60.0A AC/DC measurement span. If the expected leakage or load current stays within this window the 6200 covers the task; if peaks exceed 60.0A a higher-range meter is required.
Highlights
- Measures AC/DC leakage current up to 60.0A without breaking the circuit
- 1mA resolution detects small leakage currents in automotive and electrical systems
- Stores 99 reading groups for later review and fault diagnosis
- 25mm x 30mm clamp jaw fits around conductors up to 600V line voltage
- ±2%rdg±5dgt accuracy ensures reliable measurements for troubleshooting
Specifications
| Brand | ETCR |
|---|---|
| Model | 6200 |
| Type | Test Equipment |
| Color/Finish | Red |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
What is the clamp opening size of the ETCR 6200 meter?
The CT jaw opening measures 25mm by 30mm, allowing non-contact measurement on conductors up to that cross-section without disconnecting the circuit.
How do I store a reading on the ETCR 6200, and what is the common mistake?
Press the data-hold button after the value stabilises; the meter saves up to 99 groups, but users often press the button before the reading settles, recording a transient figure.
When will the ETCR 6200 need calibration or battery replacement?
Recalibrate annually or after heavy use to maintain the ±2%rdg±5dgt accuracy; replace the internal batteries when the low-battery indicator appears on the display.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



