Emerson Network Power
Emerson Network Power PD5002 server power supply maintenance bypass 2 NEMA L6-20R 2 NEMA 5-15/20R NEMA L14-30P
Maintenance bypass POD for GXT5 5-10kVA UPS with two L6-20R, two 5-15/20R outputs and L14-30P input
- Maintenance bypass keeps loads running during UPS service
- Automatic transfer protects equipment if UPS fails
- Plug-and-play design replaces existing POD without rewiring
- Two L6-20R and two 5-15/20R outputs connect diverse loads
- L14-30P input matches GXT5 5-10kVA UPS models
Maintenance Bypass POD for GXT5 UPS
The Vertiv Liebert PD5-002 is a power output distribution unit with an integrated maintenance bypass. It supports GXT5 5-10kVA UPS models, allowing service or replacement without interrupting power to connected equipment. It automatically transfers the load to the utility source during UPS failure. The unit replaces the existing POD box on the rear of the UPS.
Output Connectors: Two L6-20R and Two 5-15/20R
The PD5002 provides four output receptacles for load distribution. Two NEMA L6-20R connectors supply locking 20 A circuits, while two NEMA 5-15/20R connectors accept standard 15 A or 20 A plugs. This mix lets you connect both locking and non-locking power cords directly to the bypass unit. A NEMA L14-30P input plug connects the assembly to the upstream power source.
Plug-and-Play Installation
The unit is designed for tool-free installation by sliding into the UPS rear panel in place of the original POD box. Alignment with the mounting rails and full seating of the input connector are the only steps required. The most common issue is incomplete insertion, which prevents the bypass switch from engaging and leaves the load unprotected during a UPS fault.
Highlights
- Maintenance bypass keeps loads running during UPS service
- Automatic transfer protects equipment if UPS fails
- Plug-and-play design replaces existing POD without rewiring
- Two L6-20R and two 5-15/20R outputs connect diverse loads
- L14-30P input matches GXT5 5-10kVA UPS models
Specifications
No published specifications for this item yet.
Questions about this item
How is the PD5002 maintenance bypass replaced if it ever fails?
The PD5002 is a plug-and-play module that replaces the existing POD box on the back of the GXT5 UPS, allowing removal without interrupting power to the connected load.
What is the maximum input current the NEMA L14-30P connector on the PD5002 can handle continuously?
The NEMA L14-30P input connector is rated for 30 A, which sets the upper limit for total current drawn through the unit under sustained load.
Does the PD5002 add any fan noise or heat since it sits inline with the UPS all day?
The PD5002 is a passive power distribution and bypass unit with no internal fans, so it adds no audible noise and minimal heat during continuous operation.
New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
minisforum MF-SRP01 SSD Heatsink accessories barebone
- SSD Heatsink
Intel HNS2600BPS24R 2U barebone pc dual Xeon DDR4 2.80 TB C622
- Xeon Bronze Xeon Go…
- DDR4-2933/PC4-23466