We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Emerson Network Power

Emerson Network Power Liebert GXT5 Output Pod 1 PD5003 5-10kVA

SKU CH-3MCH-GVWR6

A maintenance-bypass power distribution unit for 5-10kVA UPS systems with six output receptacles and plug-and-play installation

  • Maintenance bypass enables UPS service without load interruption
  • Automatic transfer protects equipment during UPS failure events
  • Plug-and-play design replaces existing POD box directly
  • Two L6-30R and four 5-15/20R outputs distribute power
  • L14-30P input connector supplies the unit

Vertiv Liebert PD5-003 POD

The Vertiv Liebert PD5-003 is a power output distribution unit with a built-in maintenance bypass. It is designed for GXT5 5-10kVA UPS models to allow maintenance or replacement without interrupting power to connected loads. The unit automatically transfers current to the original source during UPS failures. It replaces the existing POD box on the back of the UPS.

NEMA L14-30P input and output limits

The POD connects via a single NEMA L14-30P input connector rated for 30 amps. It provides two NEMA L6-30R and four NEMA 5-15/20R output receptacles for distributing power to equipment. Total connected load must not exceed the 30-amp input rating or the individual receptacle ratings. The unit supports GXT5 UPS models ranging from 5 to 10 kVA capacity.

Plug-and-play installation and bypass operation

Installation is plug-and-play, replacing the existing POD box on the UPS rear panel. The maintenance bypass switch enables manual transfer of the load to utility power for safe UPS servicing. Automatic transfer switches the load to bypass during UPS failure events. Incorrect bypass sequencing or overloading the 30-amp input can trip breakers and drop the load.

Highlights

  • Maintenance bypass enables UPS service without load interruption
  • Automatic transfer protects equipment during UPS failure events
  • Plug-and-play design replaces existing POD box directly
  • Two L6-30R and four 5-15/20R outputs distribute power
  • L14-30P input connector supplies the unit

Specifications

No published specifications for this item yet.

Questions about this item

Should I pick the version with two NEMA L6-30R and four NEMA 5-15/20R outputs or a different configuration?

This unit provides exactly two NEMA L6-30R and four NEMA 5-15/20R receptacles; no alternative output layout is offered for the PD5-003.

What does the 5-10kVA rating mean when the pod is installed on my UPS?

The pod is built for GXT5 UPS units rated from 5 to 10 kVA, so it matches the full power range of those models without derating.

How does the NEMA L14-30P input limit what I can plug into the pod?

The L14-30P inlet caps the feed at 30 A, so the combined load on all six output receptacles must stay within that 30 A limit.

New to this? Buying PC parts with Monero — what to check, what it costs to pay, and what is never asked for.

Also in this aisle

People compared these

Same shelf, same checkout — eight coins and a 30-minute rate lock.