Emerson Climate Technologies
Emerson Climate Technologies WHITE-RODGERS 124 305111S1 DC Power Solenoid 12V 100A
A 12 V DC power solenoid rated for 100 A continuous duty with silver-alloy contacts and an isolated coil
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Continuous duty cycle supports non-stop operation
- 12 V DC coil voltage matches standard systems
- 150 A current rating handles heavy loads
- Silver alloy contacts resist wear and corrosion
- Wide -40 °F to 149 °F temperature range ensures reliability
WHITE-RODGERS 124 305111S1 DC Power Solenoid
The WHITE-RODGERS 124 305111S1 is a 12 V DC power solenoid rated for 100 A continuous duty. It uses a silver alloy SPDT contact set and an isolated coil with 13.2 ohm resistance. The unit measures 4.69 in long by 2.19 in high and operates from -40 to 149 degrees F.
Upgrade from lower-rated contactors
This solenoid replaces contactors with a current rating below 150 A or coil voltages other than 12 V DC. The jump is worth it when the application demands continuous duty at 100 A and the standard bracket mounting pattern matches the existing panel layout.
Check coil voltage and terminal threads
Verify that the control circuit supplies exactly 12 V DC and that the wiring harness uses #10-32 UNF-2A threads for the coil and 5/16 in-24 UNF-2A threads for the power contacts. Confirm the operating temperature range fits the installation environment and that the six-terminal SPDT arrangement matches the required switching logic.
Highlights
- Continuous duty cycle supports non-stop operation
- 12 V DC coil voltage matches standard systems
- 150 A current rating handles heavy loads
- Silver alloy contacts resist wear and corrosion
- Wide -40 °F to 149 °F temperature range ensures reliability
Specifications
| Brand | WHITE-RODGERS |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
What bracket and thread sizes are needed to mount the 124 series solenoid?
The unit uses a standard mounting bracket and has contact terminals with 5/16 in-24 UNF-2A threads plus coil terminals with #10-32 UNF-2A threads for secure fastening.
How do I wire the isolated coil correctly on the 305111S1 model?
Connect 12 V DC across the two #10-32 UNF-2A coil terminals; the coil is isolated so it shares no path with the main 5/16 in power contacts.
When should the silver-alloy contacts be inspected or replaced on this 150 A continuous-duty solenoid?
Check the silver-alloy contacts if voltage drop rises across the 5/16 in terminals or after extended cycling at 150 A in ambient temperatures near 149 °F.