Eemax
Eemax ED020480T2T 480V 20000W electric tankless water heater
Delivers up to 4 gpm of on-demand hot water at 480 V three-phase with a 0.7 gpm activation threshold and 20 000 W heating power
- TypeOther
- 20,000 W power delivers strong continuous hot water
- 480 V three-phase supply suits commercial and industrial sites
- 4 gpm maximum flow supports multiple fixtures at once
- 7 gpm activation starts heating with minimal draw
- 100–140 °F adjustable range meets varied temperature needs
Commercial three-phase tankless heater
The Eemax ED020480T2T is an electric tankless water heater built for commercial and industrial environments. It operates on a 480 V AC three-phase supply and draws 24 A at a full power consumption of 20000 W. The unit delivers water between 100 and 140 degrees F at a maximum flow rate of 4 gpm.
Wall-mount installation with half-inch inlet
The heater measures 12.25 in high, 18.25 in wide and 4.5 in deep for indoor wall mounting. A cold inlet size of 1/2 in connects directly to the supply line. Minimum flow activation is 0.7 gpm, so low-demand fixtures may not trigger the unit. Three-phase wiring and 480 V service must be verified before installation.
Suits high-demand commercial sites
This model suits facilities that require continuous hot water at 480 V three-phase power. It is not for residential single-phase electrical systems. Buyers who need higher flow rates or a different voltage should look at other configurations.
Highlights
- 20,000 W power delivers strong continuous hot water
- 480 V three-phase supply suits commercial and industrial sites
- 4 gpm maximum flow supports multiple fixtures at once
- 7 gpm activation starts heating with minimal draw
- 100–140 °F adjustable range meets varied temperature needs
Specifications
| Brand | EEMAX |
|---|---|
| Type | Other |
Questions about this item
How can I verify the unit is heating correctly after installation?
Confirm the display shows a delivered temperature between 100 and 140 degrees F while water flows at or above 0.7 gpm.
What comes in the box and what must I source separately?
The heater ships as a single unit; you must supply 480 V three-phase wiring, a 24 A breaker, and 1/2 in cold-water piping.
Which capacity suits a 4 gpm demand at 480 V three-phase?
This 20000 W model delivers up to 4 gpm with a 0.7 gpm activation threshold, matching the stated flow requirement.