Eaton
Eaton XTOE020BGS Overload Relay 4-20A Class 10/20/30 3P
Protects three-phase motors from 4 A to 20 A with adjustable Class 10, 20 or 30 trip curves and built-in ground-fault detection
- TypeElectronic w/ Ground Fault, ZEB12-20-GF
- ColorTransparent
- Electronic overload protection with ground-fault detection
- Adjustable trip current from 4 A to 20 A
- Selectable trip classes 10, 20 and 30
- Three-pole design for three-phase motor circuits
- Auto and manual reset options for flexible recovery
Industrial Overload Relay
The Eaton XTOE020BGS is an electronic overload relay designed for three-phase motor protection. It mounts directly to compatible Series XT mini contactors and suits industrial control panels requiring adjustable current monitoring.
Ground Fault Protection Included
This unit integrates ground fault detection within the ZEB12-20-GF module. The electronic design removes the need for separate thermal units and provides both automatic and manual reset options for operational flexibility.
4 to 20 Ampere Range
The relay handles motor loads from 4 A up to 20 A with selectable trip classes of 10, 20 and 30. It covers a wide range of small to medium motor starters but does not extend beyond the 20 A maximum setting.
Highlights
- Electronic overload protection with ground-fault detection
- Adjustable trip current from 4 A to 20 A
- Selectable trip classes 10, 20 and 30
- Three-pole design for three-phase motor circuits
- Auto and manual reset options for flexible recovery
Specifications
| Brand | Eaton |
|---|---|
| Model | XTOE020BGS |
| Type | Electronic w/ Ground Fault, ZEB12-20-GF |
| Color | Transparent |
Questions about this item
Will the electronic trip unit or ground-fault module need periodic replacement?
The unit is an electronic overload relay with integrated ground-fault protection; no user-replaceable thermal elements are required, so routine maintenance is limited to visual inspection and functional testing.
What trips first during a prolonged overload — the Class 10, 20 or 30 setting?
The relay offers selectable trip classes 10, 20 and 30; the active class determines the trip curve, so the chosen setting dictates which limit operates first under sustained overcurrent.
How much heat does the relay generate when carrying 20 A continuously?
At the maximum 20 A setting the electronic design minimises dissipation compared with thermal bimetal types, and the transparent housing allows visual confirmation of status during all-day operation.