Eaton XTMC9A01TD 3 Pole 24V DC 9 A Mini Contactor
Three-pole IEC contactor rated 9 A inductive at 24 V DC with DIN-rail or panel mounting and screw terminals
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- 24 V DC coil voltage for low-voltage control panels
- 3-pole 9 A inductive rating handles motor loads
- 1 NC auxiliary contact provides status feedback
- Screw terminals accept solid or stranded conductors
- DIN-rail or panel mount fits standard enclosures
Eaton XTMC9A01TD Mini Contactor
The Eaton XTMC9A01TD is a miniature IEC magnetic contactor designed for industrial electrical control and automation panels. It provides 3-pole switching for motors or resistive loads with a 24 V DC coil voltage. The unit mounts on DIN rail or directly onto a panel and uses screw terminals for secure wiring connections.
Suited for 9 A inductive loads
This contactor suits applications requiring a compact 9 A inductive or 20 A resistive rating in a non-reversing configuration. It includes one normally closed auxiliary contact for status signalling or interlocking. Buyers needing a reversing starter or additional auxiliary contact positions should consider a different model.
24 V DC coil voltage determines compatibility
The coil operates on 24 V DC, so the control circuit must supply this exact voltage for reliable actuation. The contactor carries a 9 A inductive full-load current rating at this coil voltage. Verify that your control supply matches 24 V DC before installation.
Highlights
- 24 V DC coil voltage for low-voltage control panels
- 3-pole 9 A inductive rating handles motor loads
- 1 NC auxiliary contact provides status feedback
- Screw terminals accept solid or stranded conductors
- DIN-rail or panel mount fits standard enclosures
Specifications
| Brand | Eaton |
|---|---|
| Model | XTMC9A01TD |
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Should I pick the 9 A inductive or the 20 A resistive rating for my load?
Use the 9 A figure for inductive loads such as motors or transformers; the 20 A figure applies only to purely resistive heating elements.
What does the 24 V DC coil voltage mean once the contactor is installed in a panel?
The coil requires a 24 V DC control supply to energise the three main poles and the single normally-closed auxiliary contact.
How does the screw-terminal interface limit the wire size I can connect?
Screw terminals accept solid or stranded conductors that fit the terminal aperture; strip length and torque should follow the manufacturer’s installation guide.