Eaton
Eaton XTCF045C10TD IEC Magnetic Contactor 4 Poles 24V DC 25A
Four-pole IEC contactor switches 25 A inductive loads at 24 V DC with 1NO auxiliary contact
- Type3" Harsh Environment, Hook-and-Loop Closure
- 25 A inductive rating handles motor loads
- 45 A resistive rating supports heating circuits
- 24 V DC coil enables low-voltage control
- 4-pole configuration switches three-phase plus neutral
- UL, CE, CSA, CCC, ATEX and IEC 60947 compliance
Eaton XTCF045C10TD 4-Pole Contactor
The Eaton XTCF045C10TD is a four-pole IEC magnetic contactor rated for 25 A inductive and 45 A resistive loads. It operates on a 24 V DC coil and includes one normally open auxiliary contact. This device suits industrial motor control and power switching panels.
Verify coil voltage and load ratings
Before ordering, confirm that your control circuit supplies 24 V DC to match the coil rating. Ensure the connected load does not exceed 25 A inductive or 45 A resistive current. Check that the 4.500 frame size and 2.28 in by 3.83 in footprint fit your panel layout.
Sustained operation within rated limits
Under continuous duty the contactor handles its full 25 A inductive rating across voltages up to 575 V AC. The open-frame design relies on ambient airflow for cooling during extended runs. Performance remains stable at the listed horsepower ratings for 208 V, 240 V, 480 V and 575 V three-phase motors.
Highlights
- 25 A inductive rating handles motor loads
- 45 A resistive rating supports heating circuits
- 24 V DC coil enables low-voltage control
- 4-pole configuration switches three-phase plus neutral
- UL, CE, CSA, CCC, ATEX and IEC 60947 compliance
Specifications
| Brand | Eaton |
|---|---|
| Model | XTCF045C10TD |
| Type | 3" Harsh Environment, Hook-and-Loop Closure |
Questions about this item
What comes in the box with the XTCF045C10TD contactor and do I need to buy a coil or enclosure separately?
The contactor is supplied as a complete unit with its 24 V DC coil already fitted and no enclosure included; no extra coil or enclosure is required unless your installation demands one.
Should I select this 25 A inductive / 45 A resistive model or a higher-frame version for my motor load?
Choose this Frame C unit when your motor full-load current is 25 A inductive or 45 A resistive or less; for larger motors you would need a higher-frame contactor.
What does the 25 A inductive rating mean when the contactor is controlling a 240 V three-phase motor?
At 240 V three-phase the 25 A inductive rating corresponds to a 10 hp motor load, so the contactor can start and run motors up to that size.