Eaton
Eaton XTCE150G00A IEC Magnetic Contactor 3 Poles 120V AC 150A
IEC magnetic contactor rated 150 A at 120 V AC, three-pole non-reversing, screw terminals, DIN-rail or panel mount, UL/CSA/IEC 60947/EN 60947 certified
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Non-reversing contactor for single-direction motor control
- 120V AC coil voltage activates the contactor reliably
- 150A amperage rating handles high-current industrial loads
- Screw terminals provide secure electrical connections
- UL Listed, CSA Certified, IEC 60947 and EN 60947 compliant with CE marking
Eaton XTCE150G00A Contactor
This Eaton XTCE150G00A is an IEC magnetic contactor rated at 150 A with a 120V AC coil. It is a non-reversing, full-voltage device built for industrial and commercial electrical control panels. The unit carries UL Listed, CSA Certified, IEC 60947 and EN 60947 compliance with CE marking.
Suitability
It suits installers who need a 150 A, three-pole contactor with a 120V AC control circuit and screw-terminal connections. It does not suit applications that require a reversing contactor, built-in auxiliary contacts, or a different coil voltage. Buyers who need a motor starter with integrated overload protection should look elsewhere.
Decisive Specification
The single specification that decides fit is the 120V AC coil voltage; the contactor will only operate with that control supply. The 150 A rating and three-pole, non-reversing action are fixed characteristics that must match the load and circuit design. Mounting flexibility with DIN rail or panel options supports installation but does not change electrical compatibility.
Highlights
- Non-reversing contactor for single-direction motor control
- 120V AC coil voltage activates the contactor reliably
- 150A amperage rating handles high-current industrial loads
- Screw terminals provide secure electrical connections
- UL Listed, CSA Certified, IEC 60947 and EN 60947 compliant with CE marking
Specifications
| Brand | Eaton |
|---|---|
| Model | XTCE150G00A |
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Will this 150 A contactor fit on the same DIN rail as my older starters?
Yes, it mounts on standard DIN rail or panel, so it shares the same rail footprint as most IEC-pattern starters.
How can I verify the 120 V AC coil is energising correctly after wiring?
Measure 120 V AC across the coil terminals; the main poles should close cleanly with no chatter.
Are auxiliary contacts or a coil suppressor included in the box?
The contactor ships without auxiliary contacts or a suppressor; both must be purchased separately.