Eaton
Eaton XTCE065D00B Magnetic Contactor 220/240V AC 3P 65A
IEC magnetic contactor for 220/240 V AC three-phase circuits, 65 A inductive and 98 A resistive, DIN-rail or panel mount with screw terminals
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Controls motors up to 65 A inductive load
- Handles 98 A resistive current for heating circuits
- Operates on 220/240 V AC coil voltage
- Three-pole IEC design for three-phase switching
- Mounts on DIN rail or panel with screw terminals
Eaton XTCE065D00B Magnetic Contactor
The Eaton XTCE065D00B is a three-pole IEC magnetic contactor rated for 65 A inductive and 98 A resistive loads. It operates on a 220/240V AC coil voltage and mounts on DIN rail or panel. The unit has no auxiliary contacts included.
Industrial control panels needing 65 A switching
This contactor suits panels that require non-reversing three-phase motor or load switching at 65 A inductive current. It is not for applications needing built-in auxiliary contacts, reversing capability, or an integrated enclosure.
65 A inductive and 98 A resistive capacity
The contactor comfortably handles inductive loads up to 65 A and resistive loads up to 98 A. It runs out when the load exceeds these ratings or when auxiliary contact functions are required.
Highlights
- Controls motors up to 65 A inductive load
- Handles 98 A resistive current for heating circuits
- Operates on 220/240 V AC coil voltage
- Three-pole IEC design for three-phase switching
- Mounts on DIN rail or panel with screw terminals
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
What auxiliary contacts must I already have to complete the installation?
This contactor includes zero auxiliary contacts, so any normally open or normally closed blocks required for your control circuit must be purchased separately and mounted on the side of the frame.
Will my existing DIN rail and panel cut-outs accept the 4.09 in height and 2.17 in width?
The unit is designed for both DIN rail and panel mounting with a frame size D footprint of 4.09 inches high by 2.17 inches wide, matching standard IEC rail spacing and common panel drill patterns.
How can I verify the coil is energising correctly at 220/240V AC?
Measure the coil terminals with a multimeter set to AC voltage; a reading between 220 and 240 volts confirms the coil is receiving the rated supply and the main poles should close.