Eaton XTCE040D00T IEC Magnetic Contactor 24V AC 3P 40A
An IEC magnetic contactor with 24 V AC coil, 3 poles, 40 A inductive and 60 A resistive ratings, screw terminals and DIN-rail or panel mounting
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- IEC-compliant 3-pole contactor rated for 40 A inductive loads
- 24 V AC coil voltage suits low-voltage control circuits
- 60 A resistive current rating supports heating and lighting loads
- DIN-rail and panel mounting options simplify cabinet installation
- Screw terminals provide secure wiring without special tools
Eaton XTCE040D00T IEC Magnetic Contactor
The Eaton XTCE040D00T is a new IEC magnetic contactor designed for industrial electrical control and automation systems. It operates on a 24V AC coil voltage and features a three-pole configuration rated for 40A inductive and 60A resistive loads. The unit mounts on DIN rail or panel and uses screw terminals for secure wiring connections.
Suits 40A inductive switching.
This contactor suits applications requiring non-reversing three-pole switching at 40A inductive current with a 24V AC control circuit. It is not for installations that require built-in auxiliary contacts, as the unit includes zero auxiliary contacts. Builders needing integrated auxiliary signaling or a reversing contactor should look at alternative models.
24V AC coil voltage decides compatibility
The single specification that decides fit is the 24V AC coil voltage, which must match the control circuit supply exactly. The contactor also delivers a 3.5 inch overall height within a Frame Size D housing, uses screw terminal connections, and carries no NEMA enclosure rating. Verify the control voltage before ordering.
Highlights
- IEC-compliant 3-pole contactor rated for 40 A inductive loads
- 24 V AC coil voltage suits low-voltage control circuits
- 60 A resistive current rating supports heating and lighting loads
- DIN-rail and panel mounting options simplify cabinet installation
- Screw terminals provide secure wiring without special tools
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How is the XTCE040D00T contactor mounted and what wiring step is often missed?
Mount it on a DIN rail or panel using the frame D base, then connect control and power cables to the screw terminals; the step often missed is tightening each screw terminal to the specified torque so connections stay secure under vibration.
What maintenance or replacement will the XTCE040D00T need over time?
The contact tips and 24 V AC coil are the wear items; inspect contact erosion periodically and replace the contactor when the 40 A inductive or 60 A resistive rating can no longer be met reliably.
What limit appears first when the XTCE040D00T runs continuously at full load?
The 40 A inductive full-load current rating is the first limit; sustained operation above this value causes contact heating and accelerated wear, so the load must stay at or below 40 A inductive.