Eaton
Eaton XTCE032C10TD IEC Magnetic Contactor 32A 24V DC 3P Non-Reversing
Three-pole IEC magnetic contactor rated 32 A inductive load, 24 V DC coil, non-reversing with 1 NO auxiliary contact and screw terminals
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Handles inductive loads up to 32 A
- Resistive rating reaches 45 A for heating circuits
- 10 hp at 240 V three-phase power
- Compact 3.5 in width fits tight DIN-rail space
- 24 V DC coil suits low-voltage control panels
Purpose and Audience
This Eaton XTCE032C10TD IEC magnetic contactor is built for industrial control panels that switch three-phase motor loads up to 32 A inductive or 45 A resistive. It suits automation engineers and panel builders who need a compact, DIN-rail or panel-mount device with a 24 V DC coil and a single normally-open auxiliary contact for status feedback.
Capacity and Headroom
The contactor carries 32 A inductive and 45 A resistive at its main poles and is rated for 10 hp at 240 V AC three-phase, giving headroom for typical fractional to mid-range motor starters. It runs out when the load exceeds those current or horsepower values or when a reversing function is required, as this model is non-reversing only.
Interface and Practical Limits
A 24 V DC coil drives the three main poles plus one auxiliary contact, all terminated with screw terminals for secure wiring. The IEC frame C housing measures 2 in high by 3.5 in wide and carries no NEMA enclosure rating, so the installer must provide a suitable cabinet or enclosure for environmental protection.
Highlights
- Handles inductive loads up to 32 A
- Resistive rating reaches 45 A for heating circuits
- 10 hp at 240 V three-phase power
- Compact 3.5 in width fits tight DIN-rail space
- 24 V DC coil suits low-voltage control panels
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Will the 32 A inductive rating of this contactor handle the same motor loads as my older IEC starter?
The contactor is rated for 32 A inductive and 45 A resistive full-load current, so it can control loads within those limits.
How can I confirm the 24 V DC coil is energised after wiring it to my DIN-rail panel?
When 24 V DC is applied to the coil terminals, the main 3-pole contacts close and the single 1NO auxiliary contact changes state, giving a clear electrical indication.
Does the box include DIN-rail clips and screw-terminal connectors, or must I buy them separately?
The unit has integral DIN-rail and panel mounting with built-in screw terminals, so no separate clips or connectors are required for installation.
Also in this aisle