Eaton XTCE032C10T Magnetic Contactor 32A 24V AC
Non-reversing IEC magnetic contactor with 24 V AC coil, 32 A inductive and 45 A resistive ratings, screw terminals, 50–60 Hz operation
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- 32 A inductive rating handles heavy motor loads
- 45 A resistive capacity supports heating circuits
- 24 V AC coil fits standard control panels
- 50–60 Hz operation works on global mains
- Screw terminals simplify field wiring
Industrial Motor Control
The Eaton XTCE032C10T is a non-reversing IEC magnetic contactor rated at 32A for inductive loads and 45A for resistive loads. It operates on a 24V AC coil at 50-60 Hz and supports horsepower ratings from 3 hp to 25 hp depending on phase and voltage. Designed for industrial electrical automation, it uses screw terminals for wire connections and features a compact frame size C suitable for panel mounting.
Verify Coil Voltage And Load
Confirm your control circuit supplies 24V AC at 50-60 Hz to match the contactor coil. Ensure the motor or load current does not exceed 32A inductive or 45A resistive ratings. Check that the available horsepower at your supply voltage falls within the 3 hp to 25 hp range. Wiring must be compatible with screw terminal connections for secure installation.
Thermal And Power Behaviour
In normal operation the contactor draws minimal coil power while switching loads up to the rated amperage. The compact frame dissipates heat through its transparent housing during continuous duty cycles. No fan or active cooling is required as the device relies on natural convection. Audible noise is limited to the mechanical actuation sound when the coil energises and de-energises.
Highlights
- 32 A inductive rating handles heavy motor loads
- 45 A resistive capacity supports heating circuits
- 24 V AC coil fits standard control panels
- 50–60 Hz operation works on global mains
- Screw terminals simplify field wiring
Specifications
| Brand | Eaton |
|---|---|
| Model | XTCE032C10T |
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
What does the 24 V AC coil voltage mean for wiring this contactor into a control panel?
The coil requires a 24 V AC supply at 50-60 Hz to energise the contactor; the panel must provide that voltage from a suitable transformer or control circuit.
How do I choose between the 32 A inductive and 45 A resistive ratings for my load?
Use the 32 A rating for motor or transformer loads and the 45 A rating for heating or lighting loads; match the rating to the load type, not the highest number.
What does the 25 hp rating mean when the contactor is installed in a three-phase system?
The 25 hp figure is the maximum three-phase motor power the contactor can switch at its rated voltage; do not exceed this limit for the connected motor.