Eaton
Eaton XTCE032C10A IEC Magnetic Contactor 32A 120V AC 3P Non-Reversing
32 A IEC magnetic contactor with 120 V AC coil, three poles, non-reversing operation and one normally-open auxiliary contact
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- 32 A inductive rating handles motor loads
- 120 V AC coil suits standard control circuits
- Three-pole design switches all phases simultaneously
- Single NO auxiliary contact provides status feedback
- DIN rail or panel mounting fits existing panels
Eaton XTCE032C10A IEC Magnetic Contactor
The Eaton XTCE032C10A is a three-pole IEC magnetic contactor rated for 32 A inductive and 45 A resistive loads. It operates on a 110/120 V AC coil and provides one normally open auxiliary contact. The unit is built for DIN rail or panel mounting in industrial control panels.
Coil voltage and auxiliary contact
The 110/120 V AC coil voltage matches common control-circuit supplies in North American panels. The single 1NO auxiliary contact allows simple status feedback or interlock wiring without extra relays. The non-reversing design suits straightforward motor-start or heating-load applications where direction change is not required.
DIN rail or panel mounting with screw terminals
The contactor mounts on standard DIN rail or directly onto a panel using screws. All power and control connections use screw terminals for secure field wiring. The compact frame measures 3.5 in wide and 2 in high, so verify available panel space before installation. Ensure the coil voltage matches the control supply to avoid nuisance tripping or coil damage.
Highlights
- 32 A inductive rating handles motor loads
- 120 V AC coil suits standard control circuits
- Three-pole design switches all phases simultaneously
- Single NO auxiliary contact provides status feedback
- DIN rail or panel mounting fits existing panels
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How often will the auxiliary contact need replacement under normal switching cycles?
The contactor includes one normally open auxiliary contact rated for the same 32 A inductive and 45 A resistive loads as the main poles, so its service life matches the primary contacts.
What thermal limit appears first when the contactor carries 32 A continuously?
The 32 A inductive full-load current rating defines the steady-state thermal boundary; exceeding it will cause the coil or contact assembly to overheat before any other parameter is reached.
How much heat does the coil generate when energised at 120 V AC all day?
The 110/120 V AC coil draws only the power needed to hold the armature closed, producing minimal heat that the 2 in by 3.5 in frame dissipates without forced cooling.