Eaton XTCE025C10T IEC Magnetic Contactor 3 Pole 24V AC 25A
Three-pole IEC magnetic contactor rated 25 A inductive and 45 A resistive at 24 V AC coil voltage with one normally-open auxiliary contact
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- IEC magnetic contactor rated for 25 A inductive loads
- 24 V AC coil voltage enables low-voltage control circuits
- Three-pole design switches three-phase motors up to 10 hp at 240 V AC
- Screw terminals and DIN rail mounting simplify panel installation
- 45 A resistive rating supports heating and lighting circuits
IEC Magnetic Contactor for 24 V AC Control Circuits
The Eaton XTCE025C10T is a three-pole IEC magnetic contactor rated for 25 A inductive and 45 A resistive loads at 24 V AC coil voltage. It suits panel builders and maintenance engineers who need reliable motor switching in industrial automation panels.
Replaces Worn or Undersized Contactors in Existing
Upgrade when an installed contactor shows contact wear, coil failure or cannot handle the required 10 hp at 240 V AC three-phase duty. The jump is worth it when the application demands a non-reversing unit with a 1 NO auxiliary contact for status feedback.
DIN-Rail or Panel Mount with Screw Terminals
The 3.5 in wide by 1.5 in high frame fits standard DIN rails or direct panel mounting using screw terminals for power and control wiring. Its open-frame design leaves enclosure selection to the integrator while freeing internal space for additional control devices.
Highlights
- IEC magnetic contactor rated for 25 A inductive loads
- 24 V AC coil voltage enables low-voltage control circuits
- Three-pole design switches three-phase motors up to 10 hp at 240 V AC
- Screw terminals and DIN rail mounting simplify panel installation
- 45 A resistive rating supports heating and lighting circuits
Specifications
| Brand | Eaton |
|---|---|
| Model | XTCE025C10T |
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
What overall width in inches does the contactor occupy on a DIN rail?
The unit is 3.5 in wide and mounts on a standard DIN rail or panel.
How is the 24 V AC coil wired during installation?
Connect the control circuit to the screw terminals marked A1 and A2 on the coil side.
When should the main contacts be replaced?
Replace them when the inductive load current exceeds 25 A or resistive load exceeds 45 A and the contacts show pitting or overheating.