Eaton XTCE025C10A IEC Magnetic Contactor 25A 120V AC 3P Non-Reversing
IEC magnetic contactor rated 25 A inductive at 110/120 V AC with three poles, one normally-open auxiliary contact and screw-terminal connections for DIN-rail or panel mounting
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- IEC-rated contactor handles 25 A inductive loads
- 120 V AC coil voltage suits standard control circuits
- Three-pole non-reversing design switches three-phase motors
- 1 NO auxiliary contact provides status feedback
- DIN-rail or panel mounting fits common enclosures
Industrial Motor Control
The Eaton XTCE025C10A is a three-pole IEC magnetic contactor rated for 25 amps inductive and 45 amps resistive load at 110/120V AC coil voltage. It suits panel builders and maintenance engineers who need reliable non-reversing switching for motors, lighting or heating circuits in commercial and light-industrial installations.
Thermal and Electrical Behaviour
The contactor carries its rated currents without an enclosure, relying on the panel environment for heat dissipation. Power draw is limited to the 110/120V AC coil during activation, while the main contacts operate silently compared with electromechanical relays, making it suitable for noise-sensitive control cabinets.
Mounting and Wiring Flexibility
The frame size C housing measures 3.5 in wide and 2 in high, fitting standard DIN rail or direct panel mounting with screw terminals for secure connections. One normally-open auxiliary contact is integrated, allowing status feedback or interlock logic without adding separate relay modules.
Highlights
- IEC-rated contactor handles 25 A inductive loads
- 120 V AC coil voltage suits standard control circuits
- Three-pole non-reversing design switches three-phase motors
- 1 NO auxiliary contact provides status feedback
- DIN-rail or panel mounting fits common enclosures
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How do I mount the XTCE025C10A on a DIN rail and which orientation keeps the 110/120 V AC coil ventilated?
Snap the contactor onto a standard DIN rail or secure it with the panel-mount holes; the coil terminals should face upward so the 110/120 V AC coil can vent heat properly.
What maintenance will the auxiliary contact and main poles need over time?
The 1NO auxiliary contact and the three main poles should be inspected periodically for contact wear; replace the contactor when the 25 A inductive or 45 A resistive rating can no longer be met.
Which limit appears first when the contactor runs continuously at full inductive load?
The 25 A inductive full-load current rating is the first limit reached under sustained use; coil heating at 110/120 V AC and the 1NO auxiliary contact rating follow if the load persists.