Eaton
Eaton XTCE015B10E Magnetic Contactor 208V AC 3P 1NO 15A
IEC magnetic contactor switches 15 A inductive loads at 208 V AC with a 1 NO auxiliary contact and DIN-rail mounting
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- IEC magnetic contactor rated for 208 V AC three-phase control
- 15 A inductive full-load current handles motor-starting duty
- 5 hp at 240 V AC three-phase for compact power switching
- 1 NO auxiliary contact provides ready status feedback
- DIN-rail or panel mounting fits standard industrial enclosures
Industrial motor control
The Eaton XTCE015B10E is an IEC magnetic contactor rated for 15 A inductive and 22 A resistive loads at 208 V AC. It switches three-phase circuits up to 5 hp at 240 V AC and mounts on DIN rail or panel for panel-builders and maintenance engineers.
Coil power and enclosure
The 208 V AC coil draws only the current required for the 10 mm frame B contactor, so steady-state dissipation stays low inside the open enclosure. With no integral fan, acoustic output is limited to the mechanical click of the three main poles and the single normally-open auxiliary.
Screw-terminal wiring
Screw terminals accept standard ferrules or bare conductors, reducing installation time compared with spring-cage alternatives. The 1NO auxiliary contact provides a ready-made feedback signal for PLCs or indicator lights without extra accessories.
Highlights
- IEC magnetic contactor rated for 208 V AC three-phase control
- 15 A inductive full-load current handles motor-starting duty
- 5 hp at 240 V AC three-phase for compact power switching
- 1 NO auxiliary contact provides ready status feedback
- DIN-rail or panel mounting fits standard industrial enclosures
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How do I mount the contactor on a DIN rail and connect the screw terminals without missing a step?
Snap the unit onto a standard DIN rail or panel-mount it using the frame B slots, then tighten each screw terminal to the specified torque so the 208 V AC coil and three power poles make solid contact.
Which components will need checking or replacement after extended service?
The 1NO auxiliary contact and main power contacts should be inspected for wear or pitting, and the 208 V AC coil should be tested for consistent pull-in after many switching cycles.
At what load does the contactor reach its thermal limit first during continuous operation?
The inductive full-load rating of 15 A at 208 V AC is the limiting threshold; sustained current above that level will cause the contactor to overheat before the 22 A resistive rating is reached.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.