Eaton
Eaton XTCE009B10T Magnetic Contactor 24V AC 3P 9A 1NO Screw
IEC magnetic contactor with 24 V AC coil, 9 A inductive rating and one normally-open auxiliary contact
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Reliable motor switching with 9 A inductive current rating
- 24 V AC coil suits common control voltage systems
- Three-pole design handles three-phase loads up to 3 hp at 240 V AC
- Screw terminals provide secure wiring for permanent installations
- Compact 2.68 in height fits tight panel spaces
Eaton XTCE009B10T Magnetic Contactor
The Eaton XTCE009B10T is a 24V AC IEC magnetic contactor designed for industrial motor control. It features a 3-pole configuration rated at 9 A inductive and 22 A resistive load. The unit includes one normally open auxiliary contact and mounts on DIN rail or panel via screw terminals. This new component suits automation panels needing reliable switching.
Suited for 3-phase motor starters up to 3 hp
Electrical contractors building pump, fan or conveyor starters will match the 9 A inductive rating and 24V AC coil voltage. Panels requiring reversing operation or higher horsepower at this frame size should select a different contactor. Installations needing enclosed NEMA ratings or spring-clamp terminals are not served by this model.
9 A inductive full-load current at 3 poles decides
The 9 A inductive rating at three poles sets the hard limit for motor loads up to 3 hp at 240V AC. Exceeding this current risks contact welding and coil overheating. Verify the motor nameplate current against the 9 A figure before specifying this contactor. The 24V AC coil voltage must also match the control circuit supply.
Highlights
- Reliable motor switching with 9 A inductive current rating
- 24 V AC coil suits common control voltage systems
- Three-pole design handles three-phase loads up to 3 hp at 240 V AC
- Screw terminals provide secure wiring for permanent installations
- Compact 2.68 in height fits tight panel spaces
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How do I mount and wire the XTCE009B10T on a DIN rail, and which step is often missed?
Snap the contactor onto a standard DIN rail or secure it with panel-mount screws, then tighten the screw terminals to the rated torque; the step most often missed is verifying the 24 V AC coil voltage before energising.
What maintenance or replacement will this 9 A IEC contactor need over time?
The main power contacts and the single 1NO auxiliary contact wear with switching cycles; plan to replace the complete unit when contact resistance rises or the auxiliary fails to close reliably.
At what load does the 3 hp / 240 V AC rating become the limiting factor during sustained operation?
The 3 hp inductive rating at 240 V AC is reached at the 9 A full-load inductive current; running above this value will cause thermal overload before the 22 A resistive limit is encountered.