We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton XTCE009B01A IEC Magnetic Contactor 1NC 120V AC 3P Non-Reversing

SKU CH-6FP8-11AGB

Non-reversing IEC magnetic contactor rated 9 A at 120 V AC with one normally closed auxiliary contact, screw terminals, DIN-rail or panel mounting, and certifications including UL, CSA.

  • TypeIndustrial Electrical Controls & Automation
  • ColorTransparent
  • Non-reversing contactor simplifies motor control circuits
  • 120 V AC coil voltage matches common industrial supplies
  • 9 A rated current handles typical three-phase loads
  • Embedded surge suppressor protects against voltage transients
  • Certified to UL, CSA, IEC 60947 and CE standards

Industrial motor starter

The Eaton XTCE009B01A is a non-reversing IEC magnetic contactor built for industrial electrical control panels. It switches three-phase loads up to 9 A using a 120 V AC coil and provides one normally closed auxiliary contact for status monitoring. The Frame B housing mounts on DIN rail or directly on a panel with screw terminals for power and control wiring.

Upgrading from smaller contactors

This unit replaces lower-rated contactors when a 9 A AC-3 rating at 400 V is required for motor-starting duty. The jump is justified when the application demands up to 1000 electrical operations at AC-3 400 V Ie or when the embedded surge suppressor adds needed transient protection. It is not suited for reversing circuits or for loads that exceed the published horsepower ratings for the given voltage and phase.

Limits of the IEC 60947 standard

The contactor is certified to IEC 60947 and EN 60947 with a CE mark, UL Listing and CSA certification. Electrical durability falls to approximately 300 operations at AC-4 400 V Ie and around 800 operations at AC-1 400 V Ie, so frequent inching or resistive switching reduces service life. The fixed 120 V AC coil voltage and single 1NC auxiliary contact cannot be changed in the field, limiting control-voltage flexibility and feedback options.

Highlights

  • Non-reversing contactor simplifies motor control circuits
  • 120 V AC coil voltage matches common industrial supplies
  • 9 A rated current handles typical three-phase loads
  • Embedded surge suppressor protects against voltage transients
  • Certified to UL, CSA, IEC 60947 and CE standards

Specifications

BrandEaton
TypeIndustrial Electrical Controls & Automation
ColorTransparent

Questions about this item

What mounting styles does the 9 A contactor support?

The contactor is compatible with both DIN Rail and Panel mounting styles.

How is the 120 V AC coil connected, and what is the common wiring mistake?

The coil connects via screw terminals; the common mistake is leaving terminal screws loose, which can cause overheating.

When should the auxiliary contact block be replaced based on the electrical operating durability ratings?

Replace after approximately 1000 operations at AC-3 400 V, 300 operations at AC-4 400 V, or 800 operations at AC-1 400 V.