We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton SU6000RT3UTAA 6000VA 5400W 208V UPS 2 L6-20R 2 L6-30R L6-30P 3U Rack/Tower TAA

SKU CH-SZS3-BKRB6 MPN SU6000RT3UTAA

Online double-conversion UPS delivers 6000VA/5400W at 208V with two L6-20R and two L6-30R outlets, L6-30P input, 10 ft cord, and network card in a 3U rack/tower TAA form

  • Online double-conversion topology protects critical loads with clean sine-wave output
  • 6000VA 5400W capacity supports dense server racks and network gear
  • 208V nominal input with 200–240V range suits North American three-phase panels
  • Four locking outlets (2 L6-20R 2 L6-30R) power diverse equipment without adapters
  • 3U rack/tower form factor fits standard cabinets or stands on the floor

High-Capacity Online UPS

The Eaton SU6000RT3UTAA is a 6000VA 5400W double-conversion UPS designed for 208V environments. It supplies continuous clean power to critical servers, network gear and storage arrays in rack or tower deployments. TAA compliance makes it suitable for federal and regulated projects.

Installation Requirements

Verify that your facility provides a single-phase 208V service rated for at least 30A with an L6-30P receptacle or hard-wire provision. The unit draws up to 24.8A at full load and ships with a 10 ft input cord. Upstream 30A circuit protection is recommended by the manufacturer.

Thermals and Power

Double-conversion topology keeps output voltage stable across 200V to 240V input without battery intervention. Internal fans maintain component temperatures during normal operation; audible noise is present but typical for 3U online units. The UPS consumes input power to sustain the inverter and charge the extended-run battery bank.

Highlights

  • Online double-conversion topology protects critical loads with clean sine-wave output
  • 6000VA 5400W capacity supports dense server racks and network gear
  • 208V nominal input with 200–240V range suits North American three-phase panels
  • Four locking outlets (2 L6-20R 2 L6-30R) power diverse equipment without adapters
  • 3U rack/tower form factor fits standard cabinets or stands on the floor

Specifications

No published specifications for this item yet.

Questions about this item

What comes in the box and what must I supply myself?

The UPS ships with a 10 ft L6-30P input cord and a network management card. You must provide a 30 A upstream breaker and any hard-wire installation materials.

Should I choose the L6-20R or L6-30R outlets for my load?

Use the two L6-20R outlets for equipment drawing up to 20 A each and the two L6-30R outlets for loads up to 30 A each; total output must not exceed 5400 W.

What does the 6000 VA / 5400 W rating mean when the UPS is running at 208 V?

At the factory-configured 208 V input the unit can deliver up to 5400 W continuous; the 6000 VA figure represents apparent power including reactive component.