Eaton PDG21F0020TFFL Circuit Breaker 20A 1 Pole 600V AC 25kA
A single-pole circuit breaker rated 20 A at 600 V AC with a 25 kA interrupting capacity at 480 V AC
- 20 A rating protects 600 V AC circuits
- 25 kA interrupting capacity at 480 V AC handles high fault currents
- Thermo-magnetic trip provides reliable overload and short-circuit protection
- Standard terminals accept 14 AWG to 1/0 AWG conductors
- Compact 6 × 1.38 × 3.5 in frame fits 225 A Frame 2 panels
Eaton PDG Series 20 A Circuit Breaker
This single-pole circuit breaker from the Eaton PDG series is rated at 20 amps and 600 V AC for commercial and industrial electrical panels. It uses a thermo-magnetic trip unit with a fixed instantaneous setting to provide overload and short-circuit protection on a three-phase system.
25 kA interrupting capacity at 480 V AC
The breaker delivers a maximum AIR rating of 25 kA at 480 V AC, giving ample headroom for typical panel fault levels in this class. It accepts conductors from 14 AWG up to 1/0 AWG on standard load-side terminals and fits within a 225 A frame size.
Rated for 158 °F maximum operating temperature
The device is designed to operate continuously in environments up to 158 degrees Fahrenheit without derating its protective characteristics. Its compact dimensions of 6 inches high, 1.38 inches wide and 3.5 inches deep allow dense mounting in standard enclosures while maintaining thermal performance.
Highlights
- 20 A rating protects 600 V AC circuits
- 25 kA interrupting capacity at 480 V AC handles high fault currents
- Thermo-magnetic trip provides reliable overload and short-circuit protection
- Standard terminals accept 14 AWG to 1/0 AWG conductors
- Compact 6 × 1.38 × 3.5 in frame fits 225 A Frame 2 panels
Specifications
| Brand | EATON |
|---|
Questions about this item
Will the 1-pole 20 A breaker fit in the same Power Defense panel that currently holds a 225 A frame unit?
Yes, the breaker uses the Frame Size 225 A / Frame 2 form factor so it mounts directly in the existing Power Defense panel.
How can I confirm the thermo-magnetic trip is operating correctly after installation?
Apply rated current and verify the fixed instantaneous trip opens the circuit; the breaker carries 20 A continuously and trips only on overcurrent per its thermo-magnetic curve.
Does the package include line-side terminals or must they be ordered separately?
The breaker ships with standard load-only terminals for 14 AWG to 1/0 AWG wire; line-side terminals are not included and must be sourced separately.