Eaton
Eaton Metered EMIT05-10 16-Outlet PDU 5.76 kVA 230 V AC
A metered power distribution unit delivers 230 V AC to 16 IEC outlets with remote current monitoring and a local display for phase balancing
- TypeOthers
- Input Voltage230 V AC
- Output Voltage230 V AC
- FeaturesPackage Contents: ePDU Metered EMIT04-10 12-Outlet PDU SPK02
- Remote monitoring of current draw via network communication
- ±1% billing grade accuracy for precise power measurement
- Hot-swap meter enables maintenance without downtime
- Daisy chain up to 4 units sharing one network connection
- Local LCD pixel display for phase balancing and provisioning
Metered Input PDU with Network Monitoring
The Eaton Metered EMIT05-10 is a horizontal power distribution unit designed for IT racks and data centres. It accepts 230 V AC input and delivers the same voltage across sixteen IEC output receptacles. A local LCD pixel display shows real-time current draw for immediate phase balancing during server provisioning. Remote monitoring is available via network communication for aggregated power management.
Suited for Racks Needing Metered Input Visibility
This unit suits administrators who need to monitor total current consumption per PDU section from a central console. The hot-swap meter allows maintenance without interrupting connected loads. Builders requiring individual outlet switching or outlet-level metering should look at switched or managed models instead. Installations limited to twelve outlets can select the smaller EMIT04-10 variant.
5.76 kVA Rating Defines Maximum Load Capacity
The 5.76 kVA power rating at 230 V AC sets the hard limit for total connected equipment. Exceeding this value risks overload and tripping. Daisy-chaining up to four units shares a single IP address while each PDU maintains its own 5.76 kVA capacity. Verify that your rack power infrastructure matches this rating before deployment.
Highlights
- Remote monitoring of current draw via network communication
- ±1% billing grade accuracy for precise power measurement
- Hot-swap meter enables maintenance without downtime
- Daisy chain up to 4 units sharing one network connection
- Local LCD pixel display for phase balancing and provisioning
Specifications
| Brand | Eaton |
|---|---|
| Series | Metered |
| Model | EMIT05-10 |
| Type | Others |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC |
| Features | Package Contents: ePDU Metered EMIT04-10 12-Outlet PDU SPK021 - INSTALLATION SPK013 - NETWORK Power Rating:5.76 kVA Form Factor:Horizontal Product Name:ePDU Metered EMIT05-10 16-Outlet PDU Output Receptacles:16 x IEC 60320 C13 Product Type:PDU Power Rating:5.76 kVA Form Factor:Horizontal Input Receptacles:1 x NEMA L6-30P |
| Shipping weight | 5.13 kg |
| Package size | 584 × 356 × 165 mm |
Questions about this item
How much heat does the 5.76 kVA metered PDU add when it runs continuously in a rack?
The unit distributes 230 V AC power to 16 IEC outlets and includes a hot-swap meter with ±1% billing-grade accuracy for monitoring load, but it does not generate significant heat of its own.
What rack mounting hardware and network connection are needed to install the horizontal EMIT05-10?
The PDU fits a horizontal rack space; the package includes installation kit SPK021 and network kit SPK013, and up to four units can be daisy-chained to share one IP address.
Can the 16-outlet metered PDU work alongside an older basic PDU that has no network monitoring?
Yes, both units deliver 230 V AC to IEC receptacles; the EMIT05-10 adds local LCD display and remote current monitoring per section while the older PDU simply provides unmonitored power distribution.
New to this? Which coin should you pay with — what to check, what it costs to pay, and what is never asked for.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.