Eaton
Eaton FH34 Thermal Unit Trip Class 20
Thermal overload unit rated for trip class 20 covering full-load currents from 4.88 to 6.2 amps and compatible with NEMA sizes 0 through 2
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Thermal overload protection for motor circuits
- Trip Class 20 provides timed response to overcurrent
- Covers 4.88 to 5.3 A and 5.7 to 6.2 A full-load ranges
- Fits NEMA Size 0, 1 and 2 starters
- Compatible with Series A200, B100 and listed Grainger part numbers
Eaton FH34 Thermal Unit
The Eaton FH34 thermal unit provides overload protection for motor starters with a Trip Class 20 rating. It suits maintenance teams and panel builders who need to match the thermal element to specific full-load current ranges of 4.88 to 5.3 A or 5.7 to 6.2 A. The transparent housing allows visual inspection of the element condition. It is designed for NEMA Size 0, 1 and 2 starters.
Compatibility Range
This thermal unit fits Series A200 and B100 motor starters across multiple configurations. It replaces elements identified by Grainger part numbers 11Z488 through 11Z497 and matches manufacturer models including B100J, B100M, B100S, B100U and B100W series with various suffix codes. Selecting the correct unit ensures the starter trips at the intended overload threshold. Buyers using non-listed starter series or current ranges outside the specified bands cannot use this unit.
Current Capacity and Headroom
The unit covers two distinct current bands: 4.88 to 5.3 A and 5.7 to 6.2 A at full load. Within these ranges the thermal element provides reliable overload tripping per Class 20 timing. Operation outside these bands will cause nuisance tripping or failure to protect the motor. The gap between 5.3 A and 5.7 A is not covered by this model. Installers must verify the motor nameplate current falls inside one of the two stated ranges before fitting.
Highlights
- Thermal overload protection for motor circuits
- Trip Class 20 provides timed response to overcurrent
- Covers 4.88 to 5.3 A and 5.7 to 6.2 A full-load ranges
- Fits NEMA Size 0, 1 and 2 starters
- Compatible with Series A200, B100 and listed Grainger part numbers
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How often should the FH34 thermal unit be replaced after repeated overload trips?
The thermal unit is a one-time trip device; after it operates at its Class 20 rating it must be replaced rather than reset.
What full-load current range triggers the trip limit on the FH34?
The unit trips between 4.88 and 5.3 A or between 5.7 and 6.2 A depending on the specific heater element installed.
Does the FH34 generate noticeable heat during continuous operation at rated current?
The thermal element dissipates heat only when current approaches the 4.88–6.2 A trip bands; below that level it runs cool and silent.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



