We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton FAZ-C1/1-SP 1A 1P Miniature Circuit Breaker

SKU CH-HEZT-X77GK

A 1 A single-pole miniature circuit breaker with C-curve thermal/magnetic protection, DIN-rail mounting and standard terminals rated to 277/480 VAC under UL 1077

  • C-curve trip protects inductive loads
  • 1 A rating suits low-current circuits
  • Single-pole DIN-rail mount saves panel space
  • UL 1077 listed for supplementary protection
  • 7 mm module width fits tight enclosures

Eaton FAZ-C1/1-SP 1A Circuit Breaker

The Eaton FAZ-C1/1-SP is a single-pole miniature circuit breaker rated at 1 A with a C-curve characteristic. It provides supplementary protection for control circuits and low-current equipment in industrial panels. The device mounts on a standard DIN rail and complies with UL 1077 for recognised component use.

DIN Rail Mounting and Panel Integration

The 17.7 mm module width per pole keeps the unit compact inside crowded enclosures. Standard terminals accept wiring without special tools and captive screws prevent lost hardware during installation. A contact position indicator shows the toggle state at a glance while finger-proof terminals improve safety during maintenance. Snap-on accessories allow future expansion without rewiring the base unit.

Thermal-Magnetic Trip Under Sustained Load

The thermal-magnetic mechanism responds to prolonged overcurrents with a delayed trip and to short circuits with a fast magnetic trip. Current-limiting action reduces let-through energy during fault conditions. The trip-free mechanism prevents the contacts from being held closed against a fault even if the toggle is forced. Rated for 277/480 VAC, the breaker is suitable for supplementary protection up to 63 A in the series.

Highlights

  • C-curve trip protects inductive loads
  • 1 A rating suits low-current circuits
  • Single-pole DIN-rail mount saves panel space
  • UL 1077 listed for supplementary protection
  • 7 mm module width fits tight enclosures

Specifications

BrandEaton

Questions about this item

What current limit triggers the thermal-magnetic trip on the FAZ-C1/1-SP under sustained overload?

The C-curve characteristic trips magnetically between 5 A and 10 A and thermally above the 1 A rating during sustained overload.

How much heat does the 17.7 mm wide module dissipate when carrying 1 A continuously all day?

Power loss at rated current is low for supplementary protection; the current-limiting design and finger-proof terminals keep temperature rise within UL 1077 limits.

Which DIN rail profile and upstream breaker rating are required to install this supplementary protector?

It snaps onto standard 35 mm DIN rail and must be backed by a branch-circuit breaker rated no higher than 63 A per UL 1077.