We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton ePDU G3 Metered Input 38U-A 8.64 kW L21-30P 24A 3P 30xC13 6xC19 1x5-20R 120/230V 8640W Network

SKU CH-WJ12-E70R0

A metered-input ePDU delivers 8.64 kW across 30 C13, 6 C19 and one 5-20R outlet with 1 % billing-grade accuracy and network monitoring

  • TypeConsumer Electronics
  • Metered input with ±1% billing-grade accuracy for precise energy reporting
  • 38 IEC C13/C19 outlets plus one NEMA 5-20R support dense rack deployments
  • Hot-swap meter allows service without removing power to connected equipment
  • Daisy-chain networking lets four units share a single IP connection
  • Rated for 60 °C operation in hot-aisle containment environments

Metered Input Power Distribution

This Eaton ePDU G3 Metered Input unit delivers billing-grade accuracy monitoring for IT and data centre environments. It measures current, voltage, power, and energy on input and branch circuits. Data is viewable on a local LCD pixel display or remotely over a network connection. Designed for high operating temperatures up to 140F or 60C.

Verify Input Plug and Outlet Needs

Confirm your facility provides a L21-30P 24A three-phase input connection compatible with 120 V AC and 230 V AC supply. The unit offers 30 IEC 60320 C13 outlets, 6 IEC 60320 C19 outlets, and 1 NEMA 5-20R outlet. Ensure your equipment plugs match these outlet types and the total load stays within 8640 W.

Suits Monitored Rack Deployments

Ideal for administrators needing precise energy reporting and load balancing in containment or hot network closets. The hot-swap meter allows servicing without power interruption. Daisy-chain networking lets four units share one IP connection. Not suited for setups requiring a different input plug, outlet mix, or non-metered basic power distribution.

Highlights

  • Metered input with ±1% billing-grade accuracy for precise energy reporting
  • 38 IEC C13/C19 outlets plus one NEMA 5-20R support dense rack deployments
  • Hot-swap meter allows service without removing power to connected equipment
  • Daisy-chain networking lets four units share a single IP connection
  • Rated for 60 °C operation in hot-aisle containment environments

Specifications

BrandEaton
TypeConsumer Electronics

Questions about this item

What outlets and cables come with the unit, and what must I supply myself?

The ePDU provides 30 IEC C13, 6 IEC C19 and 1 NEMA 5-20R receptacles; it ships with an L21-30P input plug, so you only need to bring standard C13, C19 or 5-20 power cords for your equipment.

Should I choose the 120 V or 230 V input for my 8.64 kW load?

The unit accepts both 120 V and 230 V AC on the same L21-30P feed, delivering the full 8.64 kW at 24 A three-phase regardless of which voltage your facility provides.

What does the ±1 % billing-grade accuracy mean for my actual power readings?

It guarantees that the meter reports current, voltage, power and energy within one percent of true value, so capacity-planning and cost-allocation figures are trustworthy without external calibration.