Eaton EMI104-10 PDU 42 Outlets 36 C13 6 C19 5.76 kVA 240V L6-30P 38U
Rack-mountable metered PDU delivering 5.76 kVA at 240 V through 36 C13 and 6 C19 outlets from an L6-30P input
- TypePower Distribution Units
- Front Panel LEDs38U
- Input Voltage240V
- FeaturesPower Rating: 5.76 kVA Form Factor: Rack-mountable Product T
- Weight16.00 lbs.
- Metered input monitoring tracks 5.76 kVA load in real time
- 42 outlets combine 36 C13 and 6 C19 for dense rack deployments
- 0U vertical form factor fits 38U cabinets without consuming rack units
- NEMA L6-30P input delivers 200-240V three-phase power to the unit
- Ethernet 10/100 and RS-232 ports enable remote management access
Vertical 0U 42-Outlet PDU
This metered-input power distribution unit mounts vertically in a 38U rack without consuming horizontal space. It delivers 5.76 kVA at 200–240 V through 36 IEC 60320 C13 and 6 IEC 60320 C19 outlets. The unit connects via a single NEMA L6-30P plug and includes Ethernet 10/100 and RS-232 management interfaces.
Input limits of the L6-30P connection
The NEMA L6-30P plug restricts the PDU to a 30 A, 240 V single-phase supply, capping usable power at 5.76 kVA. Both Ethernet 10/100 and RS-232 ports provide monitoring but do not increase the electrical rating. Installations must match this exact voltage and current envelope.
5.76 kVA rating decides suitability
The 5.76 kVA capacity determines whether the PDU can support the connected load without overload. Buyers whose equipment draws more than this rating at 240 V need a higher-capacity unit. The fixed outlet mix of 36 C13 and 6 C19 also limits configurations that require different connector types.
Highlights
- Metered input monitoring tracks 5.76 kVA load in real time
- 42 outlets combine 36 C13 and 6 C19 for dense rack deployments
- 0U vertical form factor fits 38U cabinets without consuming rack units
- NEMA L6-30P input delivers 200-240V three-phase power to the unit
- Ethernet 10/100 and RS-232 ports enable remote management access
Specifications
| Brand | Eaton |
|---|---|
| Model | EMI104-10 |
| Type | Power Distribution Units |
| Front Panel LEDs | 38U |
| Input Voltage | 240V |
| Features | Power Rating: 5.76 kVA Form Factor: Rack-mountable Product Type: PDU Power Rating: 5.76 kVA Form Factor: Rack-mountable Input Receptacles: NEMA L6-30P Product Name: ePDU 42-Outlets PDU Output Receptacles: 36 x IEC 60320 C13 6 x IEC 60320 C19 |
| Weight | 16.00 lbs. |
| Shipping weight | 7.25 kg |
| Package size | 1970 × 235 × 195 mm |
Questions about this item
Should I choose the 36 C13 outlets or the 6 C19 outlets for my rack equipment?
The unit provides both types simultaneously; use the 36 IEC 60320 C13 outlets for standard servers and the 6 IEC 60320 C19 outlets for higher-draw devices, all fed from the single NEMA L6-30P input.
What does the 5.76 kVA rating mean once the PDU is installed in a 240 V rack?
At 240 V the 5.76 kVA rating equals a 5.76 kW continuous load limit, so the total connected equipment must not draw more than that amount.
How does the NEMA L6-30P input connector cap the usable power in practice?
The L6-30P plug is rated for 30 A at 200–240 V, which aligns with the 5.76 kW maximum and prevents drawing more current than the branch circuit allows.