We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton EMAU06-10 Managed PDU 2U 16 Outlet 12 C13 4 C19 L6-30P 5.76 kVA

SKU CH-11FC-KF27T MPN EMAU06-10

A 2U rackmount PDU delivers 5.76 kVA through twelve C13 and four C19 outlets from a single L6-30P input with dual 20A breakers

  • Input Voltage230 V AC
  • FeaturesOutput Receptacles:12 x IEC 320-C13 4 x IEC 320-C19 Product
  • Managed 16-outlet power distribution for dense rack deployments
  • 76 kVA capacity supports high-density server and network equipment
  • 12 C13 and 4 C19 outlets fit mixed IEC power cords
  • Dual 20 A circuit breakers protect connected loads
  • Horizontal 2U form factor installs in standard 19-inch racks

16-Outlet Managed PDU for 2U Racks

The Eaton EMAU06-10 is a horizontal rackmount power distribution unit designed for 2U server cabinets. It provides managed power delivery to critical IT equipment in data centres and network closets. The unit operates on a 230 V AC input and supports a 5.76 kVA power rating.

L6-30P Input with Mixed C13 and C19 Outputs

A single NEMA L6-30P plug connects the PDU to a compatible upstream power source such as a UPS or wall circuit. Twelve IEC 320-C13 and four IEC 320-C19 receptacles supply attached servers, switches and storage arrays. Two 20 A circuit breakers protect the load banks.

Monitored Operation with Breaker Protection

Managed functionality enables remote monitoring of power consumption and environmental conditions across the rack. The dual 20 A breakers isolate faults without shutting down the entire strip. The horizontal form factor keeps cable routing tidy inside standard enclosures.

Highlights

  • Managed 16-outlet power distribution for dense rack deployments
  • 76 kVA capacity supports high-density server and network equipment
  • 12 C13 and 4 C19 outlets fit mixed IEC power cords
  • Dual 20 A circuit breakers protect connected loads
  • Horizontal 2U form factor installs in standard 19-inch racks

Specifications

BrandEaton
SeriesManaged
ModelEMAU06-10
Input Voltage230 V AC
FeaturesOutput Receptacles:12 x IEC 320-C13
4 x IEC 320-C19
Product Name:ePDU Managed 16-Outlet PDU
Form Factor:Horizontal Rackmount
Input Receptacles:1 x NEMA L6-30P
Power Rating:5.76 kVA
Power Rating:5.76 kVA
Form Factor:Horizontal Rackmount
Product Type:PDU
Shipping weight9.07 kg
Package size483 × 343 × 89 mm

Questions about this item

At what sustained load do the two 20 A circuit breakers on the EMAU06-10 trip?

Each circuit breaker trips at 20 A; the unit provides two breakers protecting separate outlet banks.

How much heat and fan noise should I expect when this PDU runs continuously at full 5.76 kVA capacity?

The PDU is a passive distribution unit with no built-in fans, so it adds no audible noise and only minimal heat from conductor losses.

What input receptacle must my rack supply to match the NEMA L6-30P plug on this unit?

The PDU requires a NEMA L6-30R outlet fed by a 230 V AC, 30 A circuit.