Eaton
Eaton EATS30P power monitoring accessory 208-240V 1U
A rack-mountable power monitoring unit with dual NEMA L6-30P inputs, single NEMA L6-30R output, Ethernet and RS-232 connectivity, and current monitoring up to 24 A at 208-240 V
- TypeMonitor Unit
- SpecificationsInput Max kW: 5.76 Plug: (2) NEMA L6-30P Cable Length (ft):
- Dimensions1.70" x 17.30" x 13.80"
- Monitors power draw up to 5.76 kW for real-time load visibility
- Dual NEMA L6-30P inputs provide redundant 208-240V feeds
- Single NEMA L6-30R outlet delivers monitored 24A output
- 1U rack height fits standard cabinets without wasting space
- 10 ft cable allows flexible placement in rack rows
Power monitoring unit for rack builds
The Eaton EATS30P is a 1U rack-mountable monitor unit that watches single-phase 208-240 V feeds up to 5.76 kW. It suits administrators who need real-time current data on critical circuits without adding a full UPS.
Dual NEMA L6-30P input with monitored output
Two NEMA L6-30P plugs on a 10 ft cord feed the unit, while a single NEMA L6-30R outlet passes power to the load. Ethernet and RS-232 links carry readings to management software, freeing the operator from manual checks.
Steady 24 A monitoring across 50-60 Hz
The unit reports continuous current at 24 A across the 50-60 Hz range with no internal circuit breakers to trip. It is not for installations that require local over-current protection or multi-phase distribution.
Highlights
- Monitors power draw up to 5.76 kW for real-time load visibility
- Dual NEMA L6-30P inputs provide redundant 208-240V feeds
- Single NEMA L6-30R outlet delivers monitored 24A output
- 1U rack height fits standard cabinets without wasting space
- 10 ft cable allows flexible placement in rack rows
Specifications
| Brand | EATON |
|---|---|
| Model | EATS30P |
| Type | Monitor Unit |
| Specifications | Input Max kW: 5.76 Plug: (2) NEMA L6-30P Cable Length (ft): 10 Voltage: 1-Phase 208-240V Current: 24A Current Monitoring: Yes Phase: Single Phase Frequency: 50-60Hz Output Outlets: (1) NEMA L6-30R Circuit Breakers: None |
| Dimensions | 1.70" x 17.30" x 13.80" |
| Shipping weight | 9.98 kg |
| Package size | 605 × 510 × 240 mm |
Questions about this item
Will the 24 A input current limit trip before my full 5.76 kW load is reached?
The unit is rated for 24 A continuous input and a maximum of 5.76 kW at 240 V, so the current limit matches the power rating at nominal voltage.
How much heat does the monitored NEMA L6-30R output generate during all-day operation?
The monitor unit itself adds minimal heat; nearly all thermal load comes from the connected equipment drawing up to 5.76 kW through the single outlet.
Do I need both NEMA L6-30P plugs connected to separate circuits for the monitor to function?
Yes, the accessory requires two L6-30P input feeds to provide monitored ATS switching to the single L6-30R output.