We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton CN15AN3AB 120VAC 3P 9A NEMA 00 Magnetic Contactor

SKU CH-5FKB-DBZ8N

Three-pole non-reversing contactor rated 9 A at 120 V AC coil with 1 NO auxiliary contact, NEMA size 00 panel mount

  • TypeIndustrial Electrical Controls & Automation
  • ColorTransparent
  • Handles 9 A inductive loads with 3-pole NEMA Size 00 design
  • Operates on 110/120 V AC coil for standard control circuits
  • Rated 1-1/2 hp at 240 V AC and 2 hp at 480 V AC three-phase
  • Compact 3.88 in height by 1.75 in width fits tight panels
  • Includes 1 NO auxiliary contact for status feedback or interlocking

Eaton CN15AN3AB Contactor

The Eaton CN15AN3AB is a NEMA Size 00 magnetic contactor rated for 9 A inductive load at 120 VAC coil voltage. It provides three-pole switching for motor-starting and lighting-control panels in industrial and commercial installations.

Upgrading From Smaller Starters

This contactor replaces fractional-horsepower starters when the load reaches 1.5 hp at 240 VAC or 2 hp at 480 VAC three-phase. The jump is worth it when the existing starter cannot handle the higher inrush current or when a NEMA-rated frame is required by specification.

Panel Mount With Screw Terminals

The unit mounts on a standard panel using the Freedom series footprint of 3.88 in height and 1.75 in width. Screw terminals accept ring or fork lugs; the most common error is over-torquing the terminal screws, which can crack the transparent housing.

Highlights

  • Handles 9 A inductive loads with 3-pole NEMA Size 00 design
  • Operates on 110/120 V AC coil for standard control circuits
  • Rated 1-1/2 hp at 240 V AC and 2 hp at 480 V AC three-phase
  • Compact 3.88 in height by 1.75 in width fits tight panels
  • Includes 1 NO auxiliary contact for status feedback or interlocking

Specifications

BrandEaton
TypeIndustrial Electrical Controls & Automation
ColorTransparent

Questions about this item

What panel cut-out dimensions does the 3.88 in by 1.75 in contactor require?

The unit measures 3.88 in high by 1.75 in wide; allow that footprint plus clearance for screw-terminal wiring on the panel.

Which coil terminals accept the 110/120V AC supply and how are they secured?

The coil connects to the screw terminals marked A1 and A2; tighten each terminal to the specified torque so the 120V AC control voltage makes reliable contact.

When should the 1NO auxiliary contact be inspected or replaced?

Check the 1NO auxiliary contact during scheduled panel maintenance; replace it if the contact shows pitting, overheating discolouration or fails to change state cleanly.