We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Eaton

Eaton AN19DN0A5E005 NEMA Motor Starter Non-Reversing 3 Pole 1NO 120V AC 5 A Overload

SKU CH-9XNH-HY3V4

A NEMA magnetic motor starter with electronic overload protection adjustable from 1 to 5 A and trip classes 10, 20, and 30

  • TypeIndustrial Electrical Controls & Automation
  • ColorTransparent
  • Non-reversing operation suits fixed-direction motor control
  • Electronic overload protection adjustable from 1 A to 5 A
  • Selectable trip classes 10A, 10, 20, 30 match application needs
  • Three-pole NEMA starter rated for 600 V AC maximum
  • 120 V AC coil voltage with single normally-open auxiliary contact

Industrial motor starter for three-phase loads

The Eaton AN19DN0A5E005 is a NEMA-rated magnetic motor starter built for non-reversing three-phase applications. It mounts on a surface and uses an electronic overload relay that can be set between 1 and 5 amperes. The coil operates at 120 volts AC while the power contacts are rated up to 600 volts AC. One normally-open auxiliary contact is included for status signalling or interlocking.

Auxiliary contact and adjustable trip class

The single 1NO auxiliary contact changes state when the starter energises, giving a simple way to drive a pilot light or feed a PLC input without extra relays. Trip class can be selected from 10A, 10, 20 or 30 to match the motor’s acceleration profile, reducing nuisance trips on high-inertia loads. Electronic overload protection replaces traditional heater elements, so there are no parts to swap when the motor rating changes.

Limits of NEMA non-reversing design

The starter only runs the motor in one direction; applications needing forward and reverse must use a different device. Overload adjustment stops at 5 amperes, so motors drawing more current require a larger frame. The 120-volt AC coil voltage is fixed, so control circuits at other voltages need a separate transformer. Trip class selection is limited to the four preset values listed.

Highlights

  • Non-reversing operation suits fixed-direction motor control
  • Electronic overload protection adjustable from 1 A to 5 A
  • Selectable trip classes 10A, 10, 20, 30 match application needs
  • Three-pole NEMA starter rated for 600 V AC maximum
  • 120 V AC coil voltage with single normally-open auxiliary contact

Specifications

BrandEaton
TypeIndustrial Electrical Controls & Automation
ColorTransparent

Questions about this item

Will the electronic overload relay on this NEMA starter need periodic recalibration or replacement after extended service?

The electronic overload relay is factory-calibrated and has no user-serviceable parts; it is designed to operate continuously within its 1 A to 5 A setting range without scheduled recalibration.

What is the first thermal or current limit reached when the starter runs at full 5 A load continuously?

The overload relay will trip according to the selected Trip Class 10A, 10, 20 or 30 curve once the sustained current exceeds the 5 A maximum setting.

How much heat does the starter dissipate and how loud is the contactor coil when energised at 120 V AC all day?

The coil draws standard NEMA holding power at 120 V AC and the contactor produces a low mechanical hum; surface mounting allows normal convection cooling without forced airflow.