Eaton
Eaton AN19BN0C5E005 NEMA Magnetic Motor Starter 5 A 600 V 3-Pole
Non-reversing NEMA magnetic motor starter with electronic overload protection adjustable from 1 to 5 A and selectable trip classes
- TypeNEMA
- ColorTransparent
- Electronic overload protection adjustable 1 A to 5 A
- Trip class selectable 10A 10 20 30 for motor safety
- Three-pole 600 V AC rating handles heavy loads
- Non-reversing NEMA starter with 1 NO auxiliary contact
- Surface-mount open design simplifies panel installation
Starter for 5 A three-phase loads
The Eaton AN19BN0C5E005 is a NEMA magnetic motor starter rated for three-phase operation up to 600 V AC. It uses electronic overload protection adjustable between 1 A and 5 A with selectable Trip Class 10A/10/20/30. The unit is non-reversing and includes one normally-open auxiliary contact. It mounts on a surface without an enclosure.
Electronic overload holds steady under continuous
The electronic overload relay maintains consistent trip behaviour during sustained load rather than only during short bursts. Trip Class settings of 10A, 10, 20 and 30 let the installer match the thermal response to the motor’s duty cycle. One normally-open auxiliary contact provides status feedback to a control circuit throughout the run.
Verify voltage, phase and mounting before ordering
Confirm the supply is three-phase and does not exceed 600 V AC. Ensure the motor’s full-load current falls within the 1 A to 5 A adjustment range. Check that surface mounting suits the panel layout and that a single normally-open auxiliary contact meets the control-scheme requirements.
Highlights
- Electronic overload protection adjustable 1 A to 5 A
- Trip class selectable 10A 10 20 30 for motor safety
- Three-pole 600 V AC rating handles heavy loads
- Non-reversing NEMA starter with 1 NO auxiliary contact
- Surface-mount open design simplifies panel installation
Specifications
| Brand | Eaton |
|---|---|
| Model | AN19BN0C5E005 |
| Type | NEMA |
| Color | Transparent |
Questions about this item
How much heat or power does the NEMA magnetic motor starter draw when it runs continuously?
The starter uses an electronic overload relay adjustable from 1 A to 5 A with trip classes 10A, 10, 20 and 30, so steady-state heat depends on the actual motor current you set.
What else must I already own for this starter to operate?
You need a three-phase supply up to 600 V AC, a motor matched to the 1 A–5 A overload range, control-circuit wiring for the 1NO auxiliary contact, and a surface to mount the open-style unit.
Will this starter work with an older motor I want to keep?
Yes, provided the motor is three-phase, rated for 600 V AC or less, and its full-load current falls between 1 A and 5 A so the electronic overload can protect it.
Also in this aisle
People compared these