Eaton AHCL1920FI 20 A 277/480 V 4-pole 4-wire 3-phase straight blade plug
A 20 A 277/480 V three-phase flanged inlet with four poles, four wires, back-wire terminals, individual wiring compartments and nylon housing rated from −40 °C to 60 °C
- Item Count1
- Typeelectrical plug
- Housing Typeelectrical plug
- 20 A 277/480 V three-phase power delivery
- Four-pole four-wire configuration supports balanced loads
- Back-wire terminal clamps simplify secure connections
- Individual wiring compartments with tapered channels ease wire insertion
- All-nylon housing withstands -40 °C to 60 °C operation
Industrial three-phase inlet
The Eaton AHCL1920FI is a straight-blade flanged inlet rated for 20 A at 277/480 V three-phase power. It uses a four-pole, four-wire configuration suitable for industrial machinery and fixed equipment connections. The red colour coding and L19-20 form factor provide quick visual identification on a panel or enclosure.
Sustained-load behaviour
Nylon construction and individual wiring compartments with tapered channels keep conductors seated during continuous operation. The housing is rated from -40 °C to 60 °C without impact, so the inlet maintains mechanical integrity and contact pressure through thermal cycling in demanding environments.
Deciding specification
The 14-8 AWG back-wire terminal clamps accept a wide range of conductor sizes for secure termination. This wire-range compatibility determines whether the inlet matches the installation's cabling without adapters or oversized lugs.
Highlights
- 20 A 277/480 V three-phase power delivery
- Four-pole four-wire configuration supports balanced loads
- Back-wire terminal clamps simplify secure connections
- Individual wiring compartments with tapered channels ease wire insertion
- All-nylon housing withstands -40 °C to 60 °C operation
Specifications
| Brand | Eaton |
|---|---|
| Item Count | 1 |
| Type | electrical plug |
| Housing Type | electrical plug |
Questions about this item
Does the Eaton AHCL1920FI run hot or draw noticeable power when left connected all day?
The flanged inlet is a passive connector rated for 20 A at 277/480 V; it generates no heat of its own and draws no power while the circuit is energised.
What wiring must I already have on site to install this inlet?
You need three-phase conductors plus neutral sized between 14 and 8 AWG, plus a matching L19-20 locking receptacle on the supply side.
Will this 4-pole 3-phase inlet work with the older 3-pole single-phase gear I keep in the panel?
No; the AHCL1920FI requires a 4-wire 3-phase 277/480 V source and will not mate with 3-pole single-phase devices.