Eaton
Eaton 9PX6KTF5 6 kVA UPS 18×5-20R 2×L6-20R 1×L6-30R
A 6 kVA battery backup with 18 NEMA 5-20R, two L6-20R, one L6-30R and hardwired outlets, plus USB, RJ-45 and RS-232 management
- Input Voltage Range100V AC to 276V AC 120V AC Nominal 200V AC Nominal 208V AC N
- Output Voltage120V AC Nominal 208V AC Nominal 220V AC Nominal 230V AC Nomi
- Outlets1 x NEMA L6-30R 18 x NEMA 5-20R 2 x NEMA L6-20R Hardwired
- Battery Run Time0.05 Hour 0.13 Hour
- Interface PortUSB RJ-45 RS-232 Serial
- Weight284
- 6 kVA capacity protects critical loads
- 18 NEMA 5-20R and 2 L6-20R outlets power many devices
- L6-30R plus hardwired input suits rack installs
- USB, RJ-45 and RS-232 ports enable remote management
- 05 to 0.13 hour runtime covers short outages
6 kVA UPS with mixed NEMA outlets
The Eaton 9PX6KTF5 is a 6 kVA battery backup designed for server rooms and network closets that need both 120 V and 208–240 V distribution. It accepts an input range of 100 V to 276 V AC and delivers nominal output at 120 V, 208 V, 220 V, 230 V and 240 V AC. The unit provides 18 NEMA 5-20R outlets, two NEMA L6-20R outlets, one NEMA L6-30R outlet and hardwired connections. Management is handled through USB, RJ-45 and RS-232 serial ports.
Replaces smaller single-voltage UPS units
This model replaces lower-capacity UPS hardware that only offers a single output voltage or fewer outlet types. The jump is worth it when equipment racks require simultaneous 120 V and 208–240 V feeds, or when the broader 100 V to 276 V input window improves compatibility with unstable utility power. Battery run times of 0.05 hour and 0.13 hour cover short outages and allow graceful shutdown.
Suits racks needing mixed 120 V and 208–240 V loads
It suits administrators who need dense 5-20R receptacle counts alongside locking L6-20R and L6-30R outlets for higher-draw gear. The 284 weight figure means the unit requires appropriate floor or rack support. Buyers who need extended battery runtime beyond the listed figures, or who require output voltages outside the 120 V to 240 V nominal range, should look at other solutions.
Highlights
- 6 kVA capacity protects critical loads
- 18 NEMA 5-20R and 2 L6-20R outlets power many devices
- L6-30R plus hardwired input suits rack installs
- USB, RJ-45 and RS-232 ports enable remote management
- 05 to 0.13 hour runtime covers short outages
Specifications
| Brand | EATON |
|---|---|
| Model | 9PX6KTF5 |
| Input Voltage Range | 100V AC to 276V AC 120V AC Nominal 200V AC Nominal 208V AC Nominal 230V AC Nominal 240V AC Nominal |
| Output Voltage | 120V AC Nominal 208V AC Nominal 220V AC Nominal 230V AC Nominal 240V AC Nominal |
| Outlets | 1 x NEMA L6-30R 18 x NEMA 5-20R 2 x NEMA L6-20R Hardwired |
| Battery Run Time | 0.05 Hour 0.13 Hour |
| Interface Port | USB RJ-45 RS-232 Serial |
| Weight | 284 |
| Shipping weight | 120.20 kg |
| Package size | 965 × 660 × 610 mm |
Questions about this item
What clearance and floor capacity are needed for the 284 lb 9PX6KTF5 tower?
The unit weighs 284 lb; place it on a level floor rated for that load and allow front clearance for the 18 NEMA 5-20R, 2 NEMA L6-20R and 1 NEMA L6-30R outlets.
How do I connect the USB, RJ-45 and RS-232 ports for monitoring, and what step is often missed?
Plug the USB cable into the server, connect the RJ-45 to the network for Web/SNMP, attach the RS-232 serial cable if required, then configure the IP address in the management card — skipping the IP setup leaves the card unreachable.
When should the internal battery modules be replaced given the 0.05 h and 0.13 h runtimes?
Runtime of 0.05 hour at full load and 0.13 hour at half load indicates the battery set; plan replacement every 3–5 years or when self-test reports reduced capacity.